Skip to content
NABL accredited testing

BS 215 Testing: Aluminium & ACSR Overhead Conductors

NABL accredited testing of aluminium & ACSR overhead conductors to BS 215: 15 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardBS 215
CoversAluminium stranded conductors for overhead power transmission; Aluminium Conductors, Steel Reinforced for overhead power transmission
Accredited tests15
AccreditationNABL, ISO/IEC 17025:2017
CategoryConductor & Insulating Mat Testing

BS 215 tests we offer

Aluminium stranded conductors for overhead power transmission

#TestClause / method
1Breaking Load of Individual WireBS 215-1 A.3 & D.2 & Table No. 2 & 3
2DiameterBS 215-1 Cl.1.2
3Diameter of Individual WireBS 215-1 Table No 2 & Table No.3
4Elongation TestBS 215-1
5Lay Ratio of Stranding ConstantBS 215-1 Cl.1.2, 3.4 & Table No 1, Appendix D
6Resistivity testBS 215-1 Cl. 4.3
7Tensile test of Individual WireBS 215-1 Cl. 4.3
8Wrapping TestBS 215-1 Cl. 4.3

Aluminium Conductors, Steel Reinforced for overhead power transmission

#TestClause / method
1Determination of Stress at 1% extensionBS 215-2 Cl. 4.3.2
2Dimensions and ConstructionBS 215-2 CL. 3
3Galvanizing Test (Mass of zinc coating)BS 215-2 Cl. & 4.1.2 & 4.3.2
4Galvanizing Test (Uniformity of zinc coating)BS 215-2 Cl. & 4.1.2 & 4.3.2
5Lay ratio of aluminium and steel wireBS 215-2 Table No.1 7 Appendix D
6Tensile Test of Aluminium and Steel WiresBS 215-2 Cl.4.3 & Cl.4.3.1 & 4.3.2
7Torsion Test or Elongation Test as appropriateBS 215-2 Cl.4.3 & Cl. & 4.3.2

How BS 215 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which BS 215 tests are NABL accredited?

All 15 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS 215 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the BS 215 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for BS 215 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of BS 215?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other conductor & insulating mat testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote