Skip to content
NABL accredited testing

IS 16107 Testing: LED Luminaire Performance

NABL accredited testing of LED luminaire performance to IS 16107: 19 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardIS 16107
CoversLED Street Lighting Luminaires; LED Luminaires
Accredited tests19
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAsk us which laboratory your BIS scheme accepts
CategoryLED Lamp & Luminaire Testing

IS 16107 tests we offer

LED Street Lighting Luminaires

#TestClause / method
1Chromaticity CoordinatesIS 16107 (Part 2/Sec 2) (Clause 9)
2Colour Rendering IndexIS 16107 (Part 2/Sec 2) (Clause 9)
3Correlated Colour TemperatureIS 16107 (Part 2/Sec 2) (Clause 9)
4LED Luminaire Life - Lumen Maintenance - Endurance TestIS 16107 (Part 2/Sec 2) (Clause 10)
5Luminous FluxIS 16107 (Part 2/Sec 2) (Clause 8.1)
6Luminous Intensity DistributionIS 16107 (Part 2/Sec 2) (Clause 8.3)
7MarkingIS 16107 (Part 2/Sec 2) (Clause 4)
8Photometric Test - Luminous fluxIS 16107 (Part 2/Sec 2) (Clause 8.4)
9Luminaire EfficacyIS 16107 (Part 2/Sec 2) (Clause 8.2)
10Total Input PowerIS 16107 (Part 2/Sec 2) (Clause 7)

LED Luminaires

#TestClause / method
1Chromaticity CoordinatesIS 16107 (Part 2/Sec 1) (Clause 9)
2Colour Rendering IndexIS 16107 (Part 2/Sec 1) (Clause 9)
3Input PowerIS 16107 (Part 2/Sec 1) (Clause 7)
4LED Luminaire Life - Lumen Maintenance - Endurance TestIS 16107 (Part 2/Sec 1) (Clause 10)
5Luminaire EfficacyIS 16107 (Part 2/Sec 1) (Clause 8.3)
6Luminous Intensity Distribution, Peak Intensity and Beam AngleIS 16107 (Part 2/Sec 1) (Clause 8.2)
7Correlated Colour TemperatureIS 16107 (Part 2/Sec 1) (Clause 9)
8Luminous FluxIS 16107 (Part 2/Sec 1) (Clause 8.1)
9MarkingIS 16107 (Part 2/Sec 1) (Clause 4)

How IS 16107 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IS 16107 tests are NABL accredited?

All 19 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 16107 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 16107 test report be used for BIS certification?

BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.

How many samples are needed for IS 16107 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 16107?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other LED lamp & luminaire testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote