IEC 61347 Testing: Lamp Control Gear Safety
NABL accredited testing of lamp control gear safety to IEC 61347: 32 tests, each against its clause.
Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.
| Standard | IEC 61347 |
|---|---|
| Covers | d.c. or a.c. Supplied Electronic Controlgear for LED Modules; Lamp Control Gear |
| Accredited tests | 32 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| Category | LED Lamp & Luminaire Testing |
IEC 61347 tests we offer
d.c. or a.c. Supplied Electronic Controlgear for LED Modules
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification | IEC 61347-1 (Clause 6) |
| 2 | Electric Strength | IEC 61347-2-13 (Clause 12) |
| 3 | Fault Condition | IEC 61347-2-13 (Clause 14) |
| 4 | Marking | IEC 61347-2-13 (Clause 7) |
| 5 | Terminals | IEC 61347-2-13 (Clause 9) |
| 6 | Construction | IEC 61347-2-13 (Clause 16) |
| 7 | Creepage Distance and Clearances | IEC 61347-2-13 (Clause 17) |
| 8 | Moisture Resistance and Insulation | IEC 61347-2-13 (Clause 11) |
| 9 | Protection against Accidental Contact with Live Parts | IEC 61347-2-13 (Clause 8) |
| 10 | Provision for Protective Earthing | IEC 61347-2-13 (Clause 10) |
| 11 | Resistance to Corrosion | IEC 61347-2-13 (Clause 20) |
| 12 | Resistance to Heat, Fire and Tracking | IEC 61347-2-13 (Clause 19) |
| 13 | Screws, Current-carrying Parts and Connections | IEC 61347-2-13 (Clause 18) |
| 14 | Transformer Heating | IEC 61347-2-13 (Clause 15) |
| 15 | Creepage Distances and Clearances | IEC 61347-2-13 Cl. 17 |
| 16 | Fault Conditions | IEC 61347-2-13 Cl. 14 |
| 17 | GENERAL REQUIREMENTS | IEC 61347-2-13 Cl. 4 |
| 18 | Provisions for Protective Earthing | IEC 61347-2-13 Cl. 10 |
| 19 | Screws, Current- Carrying Parts and Connection | IEC 61347-2-13 Cl. 18 |
Lamp Control Gear
| # | Test | Clause / method |
|---|---|---|
| 1 | Marking | IEC 61347-1 (Clause 7) |
| 2 | Protection against Accidental Contact with Live Parts | IEC 61347-1 (Clause 10) |
| 3 | Moisture Resistance and Insulation | IEC 61347-1 (Clause 11) |
| 4 | Provision for Protective Earthing | IEC 61347-1 (Clause 9) |
| 5 | Terminals | IEC 61347-1 (Clause 8) |
| 6 | Electric Strength | IEC 61347-1 (Clause 12) |
| 7 | Construction | IEC 61347-1 (Clause 15) |
| 8 | Creepage Distance and Clearances | IEC 61347-1 (Clause 16) |
| 9 | Fault Condition | IEC 61347-1 (Clause 14) |
| 10 | No-load Output Voltage | IEC 61347-1 (Clause 20) |
| 11 | Resistance to Corrosion | IEC 61347-1 (Clause 19) |
| 12 | Resistance to Heat, Fire and Tracking | IEC 61347-1 (Clause 18) |
| 13 | Screws, Current-carrying Parts and Connections | IEC 61347-1 (Clause 17) |
How IEC 61347 testing works
- Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.
Frequently asked questions
Which IEC 61347 tests are NABL accredited?
All 32 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IEC 61347 shown next to it. The report carries the NABL accreditation mark for these tests.
Is the IEC 61347 test report accepted outside India?
NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.
How many samples are needed for IEC 61347 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IEC 61347?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other LED lamp & luminaire testing
- IS 10322 Luminaires
- IS 15885 LED Drivers (Control Gear)
- IS 16102 Self-Ballasted LED Lamps
- IS 16103 LED Modules for General Lighting
- IS 16107 LED Luminaire Performance
- IS 16104 LED Module Control Gear (Performance)
- IS 16106 LED Photometric & Electrical Measurements
- IEC 60598 Luminaire Safety
- IEC 62031 LED Module Safety
- IEC 62560 Self-Ballasted LED Lamps
- IEC 62612 Self-Ballasted LED Lamp Performance
- IEC 62722 Luminaire Performance
- IEC 62717 LED Module Performance
- IES LM 79 LED Photometric Measurements
- IEC 62384 LED Control Gear Performance
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- Overhead Line Hardware Testing 128 accredited tests
- LED Lamp & Luminaire Testing 573 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 312 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.