IS 4289 Testing: Flexible Lift Cables
NABL accredited testing of flexible lift cables to IS 4289: 32 tests, each against its clause.
| Standard | IS 4289 |
|---|---|
| Covers | Flexible Cable for Lifts and other Flexible Connections, Part-1 Elastomeric Insulated Cables; Flexible Cable for Lifts and other Flexible Connections, Part-2 PVC Insulated Circular Cables |
| Accredited tests | 32 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| BIS-recognised testing | Ask us which laboratory your BIS scheme accepts |
| Category | Cable & Wire Testing |
IS 4289 tests we offer
Flexible Cable for Lifts and other Flexible Connections, Part-1 Elastomeric Insulated Cables
| # | Test | Clause / method |
|---|---|---|
| 1 | Ageing In Air Bomb On Sheath | IS 4289 (P-1) 1984 Cl 17.1(f) 2,IS 10810 (P-56) Cl 1to 11.3 |
| 2 | Ageing In Oxygen Bomb | IS 4289 (P-1) 1984 Cl 17.1(e) 3,IS 10810 (P-16) Cl 1to 11.3 |
| 3 | Annealing | IS 4289 (P-1) 1984 Cl 17.1(b),IS 10810 (P-1) Cl 1 to11.2 |
| 4 | Conductor Resistance | IS 4289 (P-1) 1984 Cl 17.1(c),IS 10810 (P-5) Cl 1 to11.2, Table-1 |
| 5 | Elongation at Break on Insulation | IS 4289 (P-1) 1984 Cl 17.1(e) 1,IS 10810 (P-7) Cl 1to 11.2 |
| 6 | Elongation at Break on Sheath | IS 4289 (P-1) 1984 Cl 17.1(f) 1,IS 10810 (P-7) Cl 1 to 11.2 |
| 7 | Flammability | IS 4289 (P-1) 1984 Cl 17.1 (k),IS 10810 (P-53) Cl 1 to 11.3 |
| 8 | High Voltage | IS 4289 (P-1) 1984 Cl 17.1(g) and Cl 18.1,,IS 10810(P-45) Cl 1 to 11.2 |
| 9 | Insulation Resistance | IS 4289 (P-1) 1984 Cl 17.1(h),IS 10810 (P-43) Cl 1to 11.2 |
| 10 | Oil Resistance Elongation at break on Sheath | IS 4289 (P-1) 1984 Cl 17.1 (f) 3,IS 10810 (P-31) 1984,IEC 60840 Clause 12.5.3 |
| 11 | Oil Resistance Tensile Strength on Sheath | IS 4289 (P-1) 1984 Cl 17.1 (f) 3,IS 10810 (P-31) 1984,IEC 60840 Clause 12.5.3 |
| 12 | Persulphate Test | IS 4289 (P-1) 1984 Cl 17.1(a),IS 10810 (P-4) Cl 1 ro11.3 |
| 13 | Tear Resistance Test | IS 4289 (P-1) 1984 Cl 17.1(f) 4, IS 10810 (P-17) Cl 1to 11.3 |
| 14 | Tensile Strength on Insulation | IS 4289 (P-1) 1984 Cl 17.1(e) 1,IS 10810 (P-7) Cl 1to 11.2 |
| 15 | Tensile Strength on Sheath | IS 4289 (P-1) 1984 Cl 17.1(f) 1,IS 10810 (P-7) Cl 1 to 11.2 |
| 16 | Thermal Ageing In Air Oven On Insulation | IS 4289 (P-1) 1984 Cl 17.1(e) 2,IS 10810 (P-11) Cl 1to 11.2 |
| 17 | Thickness Of Insulation and Sheath (mm) | IS 4289 (P-1) 1984 Cl 17.1(d),IS 10810 (P-6):Cl 1 to11.2 |
Flexible Cable for Lifts and other Flexible Connections, Part-2 PVC Insulated Circular Cables
| # | Test | Clause / method |
|---|---|---|
| 1 | Annealing | IS 4289 (P-2) 2000 Cl 18.1 (a) i,IS 10810 (P-1) Cl 1 to 11.2 2014 |
| 2 | Cold Bend Test | IS 4289 (P-2) 2000 Cl 18.4,IS 10810 (P-20) Cl 1to 11.3 |
| 3 | Cold Impact Test | IS 4289 (P-2) 2000 Cl 18.4,IS 10810 (P-21) Cl 1to 11.3 |
| 4 | Conductor Resistance | IS 4289 (P-2) 2000 Cl 18.1 (a) ii,IS 10810 (P-5) Cl 1 to 11.2, Table-1 |
| 5 | Flammability | IS 4289 (P-2) 2000 Cl 18.1(g),IS 10810 (P-53) Cl 1 to11.3 |
| 6 | Heat Shock Test On Insulation and Sheath | IS 4289 (P-2) 2000 Cl 18.1(c) iv,IS 10810 (P-14) Cl 1to 11.3 |
| 7 | High Voltage Test (Water Immersion) | IS 4289 (P-2) 2000 Cl 18.1(d) and 19..2,IS 10810(P-45) Cl 1 to 11.2 |
| 8 | Insulation Resistance | IS 4289 (P-2) 2000 Cl 18.1(e),IS 10810 (P-43) Cl 1to 11.2 |
| 9 | Loss of Mass In Air Oven | IS 4289 (P-2) 2000 Cl 18.1(c) iii, IS 10810 (P-10) Cl 1to 11.3 |
| 10 | Shrinkage Test on insulation and Sheath | IS 4289 (P-2) 2000 Cl 18.1(c) v,IS 10810 (P-12) Cl 1to 11.3 |
| 11 | Tensile Strength on Insulation and Outer Sheath | IS 4289 (P-2) 2000 Cl 18.1 (c) i,IS 10810 (P-7) Cl 1 to 11.2 |
| 12 | Test For Thickness Of Insulation and Sheath | IS 4289 (P-2) 2000 Cl 18.1 (b),IS 10810 (P-6) Cl 1 to 11.2 |
| 13 | Thermal Ageing In Air Oven On Insulation and Sheath | IS 4289 (P-2) 2000 Cl 18.1(c) ii,IS 10810 (P-11) Cl 1to 11.2 |
| 14 | Thermal Stability Test on Sheath | IS 4289 (P-2) 2000 Cl 18.1 (c) vi,IS 10810 (P-60) Cl 1 to 11.3 |
| 15 | Elongation on Insulation and Sheath | IS 4289 (P-2) 2000 Cl 18.1 (c) i,IS 10810 (P-7) Cl 1 to 11.2 |
How IS 4289 testing works
- Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.
Frequently asked questions
Which IS 4289 tests are NABL accredited?
All 32 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 4289 shown next to it. The report carries the NABL accreditation mark for these tests.
Can the IS 4289 test report be used for BIS certification?
BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.
How many samples are needed for IS 4289 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IS 4289?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other cable & wire testing
- IS 10810 Methods of Test for Cables
- IS 7098 XLPE Insulated Cables
- IS 1554 PVC Insulated Heavy Duty Cables
- IS 9968 Elastomer Insulated Cables
- IS 17505 Fire Survival Cables
- IS 6380 Elastomeric Insulation & Sheath for Cables
- IS 5831 PVC Insulation & Sheath for Cables
- IS 16246 Fire Resistant Circuit Integrity Cables
- IS 8130 Conductors for Insulated Cables
- IS 17293 Solar PV Cables
- IS 14494 Flexible Mining Cables
- IS 17048 HFFR Cables
- IS 694 PVC Insulated Cables
- IS 2465 Cables for Motor Vehicles
- IS 3975 Steel Armour Wires & Tapes for Cables
- IS 14255 Aerial Bunched Cables
- IS 9857 Welding Cables
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- LED Lamp & Luminaire Testing 144 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 225 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.