Skip to content
NABL accredited testing

BS EN 50525 Testing: Low Voltage Energy Cables

NABL accredited testing of low voltage energy cables to BS EN 50525: 92 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardBS EN 50525
CoversLow Voltage Energy Cables – Single Core non- sheathed cables with halogen-free cross-linked insulation and low emission of smoke; Flexible Cables with Thermoplastic PVC Insulation; Single Core non-sheathed cables with thermoplastic PVC Insulation; Low Voltage Energy Cables – Flexible Cables with cross- linked elastomeric insulation; Low Voltage Energy Cables – Multicore Cables with cross- linked Silicon Rubber insulation; Single core cables with crosslinked silicone rubber insulation; Single core non-sheathed cables with crosslinked EVA insulation; Low Voltage Energy Cables - Part 1 General Requirements; Low Voltage Energy Cables : General Requirements
Accredited tests92
AccreditationNABL, ISO/IEC 17025:2017
CategoryCable & Wire Testing

BS EN 50525 tests we offer

Low Voltage Energy Cables – Single Core non- sheathed cables with halogen-free cross-linked insulation and low emission of smoke

#TestClause / method
1Ageing in Air Oven Elongation testBS EN 50525-3-41
2Ageing in Air Oven Tensile strengthBS EN 50525-3-41
3Cold Impact TestBS EN 50525-3-41
4ConductivityBS EN 50525-3- 41
5Conductor ResistanceBS EN 50525-3-41
6Elongation at break on Insulation and SheathBS EN 50525-3-41
7Elongation Test at Low TemperatureBS EN 50525-3-41
8Halogen Acid Gas Evolution / Corrosive & halogen acid gasBS EN 50525-3-41
9High Voltage test (Water immersion)BS EN 50525-3-41
10High Voltage test at room temperatureBS EN 50525-3-41
11Hot deformation test / Pressure Test at High TemperatureBS EN 50525-3-41
12Hot Set TestBS EN 50525-3-41
13Insulation ResistanceBS EN 50525-3-41
14Ozone Resistance TestBS EN 50525-3-41
15pHBS EN 50525-3-41
16Smoke Density under Fire ConditionsBS EN 50525-3-41
17Tensile strength at break on Insulation and SheathBS EN 50525-3-41
18Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-3-41
19Test under Fire Conditions / Flammability test (unaffected portion/ under period of Burning)BS EN 50525-3-41

Flexible Cables with Thermoplastic PVC Insulation

#TestClause / method
1Ageing in Air Oven Elongation testBS EN 50525-2-11
2Ageing in Air Oven Tensile StrengthBS EN 50525-2-11
3Bending Test at Low TemperatureBS EN 50525-2-11
4Conductor ResistanceBS EN 50525-2-11
5Elongation at break on Insulation and SheathBS EN 50525-2-11
6Elongation Test at Low TemperatureBS EN 50525-2-11
7Flexing TestBS EN 50525-2-11
8Heat Shock TestBS EN 50525-2-11
9Hot deformation test / Pressure Test at High TemperatureBS EN 50525-2-11
10Long Term Resistance of Insulation to d.cBS EN 50525-2-11
11Loss of MassBS EN 50525-2-11
12Mechanical Strength of Strain Bearing MemberBS EN 50525-2-11
13Tensile strength at break on Insulation and SheathBS EN 50525-2-11
14Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-2-11
15Test under Fire Conditions / Flammability test (unaffected portion/ under period of Burning)BS EN 50525-2-11
16Thermal StabilityBS EN 50525-2-11
17Voltage Test at 2000 V or 2500 VBS EN 50525-2-11

Single Core non-sheathed cables with thermoplastic PVC Insulation

#TestClause / method
1Ageing in Air Oven ElongationBS EN 50525-2-31
2Ageing in Air Oven Tensile StrengthBS EN 50525-2-31
3Bending Test at Low TemperatureBS EN 50525-2-31
4Conductor ResistanceBS EN 50525-2-31
5elongation at break on Insulation and SheathBS EN 50525-2-31
6Elongation Test at Low TemperatureBS EN 50525-2-31
7Heat Shock TestBS EN 50525-2-31
8Hot deformation test / Pressure Test at High TemperatureBS EN 50525-2-31
9Long Term Resistance of Insulation to d.cBS EN 50525-2-31
10Loss of MassBS EN 50525-2-31
11Measurement of Overall DimensionsBS EN 50525-2-31
12Measurement of Thickness of Insulation & SheathBS EN 50525-2-31
13Tensile strength at break on Insulation and SheathBS EN 50525-2-31
14Test under Fire Conditions / Flammability test (unaffected portion/ under period of Burning)BS EN 50525-2-31
15Thermal StabilityBS EN 50525-2-31
16Voltage Test at 2000 V or 2500 VBS EN 50525-2-31

Low Voltage Energy Cables – Flexible Cables with cross- linked elastomeric insulation

#TestClause / method
1Elongation at break on Insulation and SheathBS EN 50525-2-21
2Ageing in Air Oven Elongation testBS EN 50525-2-21
3Ageing in Air Oven Tensile strengthBS EN 50525-2-21
4Conductor ResistanceBS EN 50525-2-21
5Elongation Test at Low temperatureBS EN 50525-2-21
6High Voltage test (Water immersion)BS EN 50525-2-21
7High Voltage test at room temperatureBS EN 50525-2-21
8Hot Set TestBS EN 50525-2-21
9Ozone Resistance TestBS EN 50525-2-21
10Tensile strength at break on Insulation and SheathBS EN 50525-2-21
11Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-2-21
12Test under Fire Conditions / Flammability TestBS EN 50525-2-21

Low Voltage Energy Cables – Multicore Cables with cross- linked Silicon Rubber insulation

#TestClause / method
1Ageing in Air Oven Elongation testBS EN 50525-2-83
2Ageing in Air Oven Tensile strengthBS EN 50525-2-83
3Cold Impact TestBS EN 50525-2-83
4Conductor ResistanceBS EN 50525-2-83
5elongation at break on Insulation and SheathBS EN 50525-2-83
6Elongation Test at Low TemperatureBS EN 50525-2-83
7High Voltage test (Water immersion)BS EN 50525-2-83
8High Voltage test at room temperatureBS EN 50525-2-83
9Hot Set TestBS EN 50525-2-83
10Ozone Resistance TestBS EN 50525-2-83
11Tensile strength at break on Insulation and SheathBS EN 50525-2-83
12Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-2-83

Single core cables with crosslinked silicone rubber insulation

#TestClause / method
1Ageing in Air Oven ElongationBS EN 50525-2-41
2Ageing in Air Oven Tensile StrengthBS EN 50525-2-41
3Conductor ResistanceBS EN 50525-2-41
4Insulation ResistanceBS EN 50525-2-41
5Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-2-41

Single core non-sheathed cables with crosslinked EVA insulation

#TestClause / method
1Ageing in Air Oven Elongation testBS EN 50525-2-42
2Ageing in Air Oven Tensile TestBS EN 50525-2-42
3Conductor ResistanceBS EN 50525-2-42
4Insulation ResistanceBS EN 50525-2-42
5Test for eccentricity and Thickness of insulation and sheath / Overall DimensionsBS EN 50525-2-42

Low Voltage Energy Cables - Part 1 General Requirements

#TestClause / method
1Fluorine TestBS EN 50525-1
2Long Term Resistance of Insulation to D.CBS EN 50525-1
3Voltage Test at 2000 V or 2500 VBS EN 50525-1
4Voltage Test on cores at 2500 VBS EN 50525-1

Low Voltage Energy Cables : General Requirements

#TestClause / method
1Assessment of halogens for all non-metallic materialsBS EN 50525-1
2Insulation ResistanceBS EN 50525-1

How BS EN 50525 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which BS EN 50525 tests are NABL accredited?

All 92 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS EN 50525 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the BS EN 50525 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for BS EN 50525 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of BS EN 50525?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other cable & wire testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote