Skip to content
NABL accredited testing

IS 398 Testing: Aluminium Conductors for Overhead Lines

NABL accredited testing of aluminium conductors for overhead lines to IS 398: 40 tests, each against its clause.

StandardIS 398
CoversAluminum Conductor For Overhead Transmission Purpose, Part-2 Galvanised Steel Reinforced; High conductivity aluminium alloy stranded conductors; Aluminium conductors for overhead transmission purposes (ACSR); Aluminium conductors for overhead transmission purposes (AAC); Aluminium conductors for overhead transmission purposes (AAAC)
Accredited tests40
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAsk us which laboratory your BIS scheme accepts
CategoryConductor & Insulating Mat Testing

IS 398 tests we offer

Aluminum Conductor For Overhead Transmission Purpose, Part-2 Galvanised Steel Reinforced

#TestClause / method
1Breaking test of individual wiresIS 398 (Pt 2):1996
2Ductility test (Elongation)IS 398 (Pt.2):1996
3Ductility test (Torsion test)IS 398 (Pt.2):1996
4Galvanizing test b. weight of zinc coatingIS 398 (Pt.2):1996, IS 4826:1979, IS: 10810 (Pt 41)1984
5Galvanizing test a. uniformity of zinc coatingIS 398 (Pt.2):1996, IS 4826:1979, IS:10810(Pt 40)1984
6Measurement of diameter of individual aluminium and steel wiresIS 398 (Pt 2):1996
7Measurement of lay ratioIS 398 (Pt 2):1996
8Resistance testIS 398 (Pt.2):1996
9Stress-strain testIS 398 (P-2) Cl 13.11 & 14.1 c
10Surface condition testIS 398 (P-2) Cl 13.9 & 14.1 a
11Test for ultimate breaking load on stranded conductorIS 398 (P-2) Cl 13.10 & 14.1 b
12Wrapping testIS 398 (Pt.2):1996

High conductivity aluminium alloy stranded conductors

#TestClause / method
1DC resistance testCl. 14, Cl.16.10 and Table 3 of IS 398 (Pt. 6)
2Breaking load testCl. 14, Cl.16.5 and Table 2 of IS 398 (Pt. 6)
3Elongation testCl. 14, Cl.16.6 and Table 1 of IS 398 (Pt. 6)
4Freedom From DefectsCl. 8 of IS 398 (Pt. 6)
5Measurement of diameterCl. 14, Cl.16.4 and Table 2 of IS 398 (Pt. 6)
6Measurement of lay ratioCl. 14, Cl.16.3 and Table 4 of IS 398 (Pt. 6)
7Resistivity testCl. 14 and Cl. 16.7 of IS 398 (Pt. 6)
8Stress-strain test on conductorIS 398 (Pt 6):2021
9Test for ultimate Tensile Strength testIS 398 (Pt 6):2021
10Visual examinationCl. 14, Cl.16.2 of IS 398 (Pt. 6)
11Wrapping testCl. 14 and Cl. 16.8 of IS 398 (Pt. 6)

Aluminium conductors for overhead transmission purposes (ACSR)

#TestClause / method
1Ductility test- (Elongation)Cl.14.1(g) Cl.13.4,13.4.2 of IS 398 (Pt-2)
2Ductility test-(Torsion test)Cl.14.1(g) Cl. 13.4,13.4.1 of IS 398 (Pt-2)
3Galvanizing test- b.weight of zinc coatingCl.14.1(k) Cl. 13.7of IS 398 (Pt-2)
4Measurement of diameter of individual aluminium and steel wiresCl.14.1(d) Cl.13.2(Table 1,2) of IS 398 (Pt-2)
5Measurement of lay ratioCl.14.1(e) Cl. 13.8(Table 4) of IS 398 (Pt-2)
6Resistance testCl.14.1(j) Cl. 13.6of IS 398 (Pt-2)
7Wrapping testCl.14.1(h) Cl.13.5.1,13.5.2 of IS 398 (Pt-2)
8Breaking test of individual wiresCl.14.1(f) Cl.13.3(Table 1 & 2)of IS 398 (Pt-2)

Aluminium conductors for overhead transmission purposes (AAC)

#TestClause / method
1Wrapping testCl.13.1(c) Cl.12.4 of IS 398 (Pt-1)
2Breaking test of individual wiresCl.13.1(b) Cl.12.3, (Table -1,2) of IS 398 (Pt-1)
3Measurement of lay ratioCl.13.1(e) Cl.12.6 &(Table -3) of IS 398 (Pt-1)
4Resistance testCl.13.1(d) Cl.12.5 (Table -1,2) of IS 398(Pt-1)
5Measurement of diameter of individual aluminium wiresCl.13.1(a) Cl.12.2(Table -1,2) of IS 398 (Pt-1)

Aluminium conductors for overhead transmission purposes (AAAC)

#TestClause / method
1Breaking test of individual aluminium low wiresCl. of IS 398 (Pt-4), 12.2, (Table-1,2),12.3
2Elongation test of individual aluminium alloy wiresCl. of IS 398(Pt- 4),12.2 (Table-1,2), 12.3
3Measurement of diameter of individual aluminium alloy wiresCl. of IS 398 (Pt- 4), 3.1.2,Table 1,2
4Resistance test of individual aluminium alloy wiresCl. IS 398 (Pt- 4),12.4, (Table-1,2)

How IS 398 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IS 398 tests are NABL accredited?

All 40 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 398 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 398 test report be used for BIS certification?

BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.

How many samples are needed for IS 398 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 398?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other conductor & insulating mat testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote