IS 10322 Testing: Luminaires
NABL accredited testing of luminaires to IS 10322: 52 tests, each against its clause. Testing is available at a BIS-recognised laboratory, so the report can be used for BIS certification.
| Standard | IS 10322 · BIS certification under IS 10322 |
|---|---|
| Covers | Fixed General Purpose Luminaries; Hand Lamps; Rope Lights; Lighting Chain; Lighting Chains |
| Accredited tests | 52 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| BIS-recognised testing | Available |
| Category | LED Lamp & Luminaire Testing |
IS 10322 tests we offer
Fixed General Purpose Luminaries
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaries | IS 10322 (Part 5/Sec 1) Cl. 5 |
| 2 | Construction | IS 10322 (Part 5/Sec 1) Cl. 7 |
| 3 | Creepage Distance and Clearance | IS 10322 (Part 5/Sec 1) Cl. 8 |
| 4 | Endurance Test and Thermal Test | IS 10322 (Part 5/Sec 1) Cl. 13 |
| 5 | External And Internal Wiring | IS 10322 (Part 5/Sec 1) Cl. 11 |
| 6 | GENERAL TEST REQUIREMENTS | IS 10322 (Part 5/Sec 1) Cl. 4 |
| 7 | Insulation Resistance and Electric Strength | IS 10322 (Part 5/Sec 1) Cl. 15 |
| 8 | Marking | IS 10322 (Part 5/Sec 1) Cl. 6 |
| 9 | Protection Against Electric Shock | IS 10322 (Part 5/Sec 1) Cl. 12 |
| 10 | Provision for Earthing | IS 10322 (Part 5/Sec 1) Cl. 9 |
| 11 | Resistance to dust and moisture | IS 10322 (Part 5/Sec 1) Cl. 14 |
| 12 | Resistance to Heat, Fire and Tracking | IS 10322 (Part 5/Sec 1) Cl. 16 |
| 13 | Terminals | IS 10322 (Part 5/Sec 1) Cl. 10 |
Hand Lamps
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaries | IS 10322 (Part 5/Sec 6) Cl. 5 |
| 2 | Creepage Distance and Clearance | IS 10322 (Part 5/Sec 6) Cl. 8 |
| 3 | Endurance Test and Thermal Test | IS 10322 (Part 5/Sec 6) Cl. 13 |
| 4 | External And Internal Wiring | IS 10322 (Part 5/Sec 6) Cl. 11 |
| 5 | Insulation Resistance and Electric Strength | IS 10322 (Part 5/Sec 6) Cl. 15 |
| 6 | Marking | IS 10322 (Part 5/Sec 6) Cl. 6 |
| 7 | Protection Against Electric Shock | IS 10322 (Part 5/Sec 6) Cl. 12 |
| 8 | Provision for Earthing | IS 10322 (Part 5/Sec 6) Cl. 9 |
| 9 | Resistance to dust and moisture | IS 10322 (Part 5/Sec 6) Cl. 14 |
| 10 | Resistance to Heat, Fire and Tracking | IS 10322 (Part 5/Sec 6) Cl. 16 |
| 11 | Terminals | IS 10322 (Part 5/Sec 6) Cl. 10 |
| 12 | Construction | IS 10322 (Part 5/Sec 6) Cl. 7 |
| 13 | General Test Requirements | IS 10322 (Part 5/Sec 6) Cl. 5 |
Rope Lights
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaries | IS 10322 (Part5/Sec 9) Cl. 21.5 |
| 2 | Construction | IS 10322 (Part5/Sec 9) Cl. 21.7 |
| 3 | Creepage Distance and Clearance | IS 10322 (Part5/Sec 9) Cl. 21.8 |
| 4 | Endurance Test and Thermal Test | IS 10322 (Part5/Sec 9) Cl. 21.13 |
| 5 | External And Internal Wiring | IS 10322 (Part5/Sec 9) Cl. 21.11 |
| 6 | General test requirements | IS 10322 (Part5/Sec 9) Cl. 21.4 |
| 7 | Insulation Resistance and Electric Strength | IS 10322 (Part5/Sec 9) Cl. 21.15 |
| 8 | Marking | IS 10322 (Part5/Sec 9) Cl. 21.6 |
| 9 | Protection Against Electric Shock | IS 10322 (Part5/Sec 9) Cl. 21.12 |
| 10 | Resistance to Dust, Solid Objects and Moisture | IS 10322 (Part5/Sec 9) Cl. 21.14 |
| 11 | Resistance to Heat, Fire and Tracking | IS 10322 (Part5/Sec 9) Cl. 21.16 |
| 12 | Terminals | IS 10322 (Part5/Sec 9) Cl. 21.10 |
| 13 | Test for Interconnecting Connector for use in Lighting chain | IS 10322 (Part5/Sec 9) Annex A.16 |
Lighting Chain
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaries | IS 10322 (Part 5/Sec 7) Cl. 20.5 |
| 2 | Creepage Distance and Clearance | IS 10322 (Part 5/Sec 7) Cl. 20.8 |
| 3 | Endurance Test and Thermal Test | IS 10322 (Part 5/Sec 7) Cl. 20.13 |
| 4 | External And Internal Wiring | IS 10322 (Part 5/Sec 7) Cl. 20.11 |
| 5 | Insulation Resistance and Electric Strength | IS 10322 (Part 5/Sec 7) Cl. 20.15 |
| 6 | Marking | IS 10322 (Part 5/Sec 7) Cl. 20.6 |
| 7 | Protection Against Electric Shock | IS 10322 (Part 5/Sec 7) Cl. 20.12 |
| 8 | Resistance to Heat, Fire and Tracking | IS 10322 (Part 5/Sec 7) Cl. 20.16 |
| 9 | Terminals | IS 10322 (Part5/Sec 7) Cl. 20.10 |
| 10 | Test for Interconnecting Connector for use in Lighting chain | IS 10322 (Part 5/Sec 7) Annex A.16 |
Lighting Chains
| # | Test | Clause / method |
|---|---|---|
| 1 | Construction | IS 10322 (Part 5/Sec 7) Cl. 20.7 |
| 2 | General test requirements | IS 10322 (Part 5/Sec 7) Cl. 20.4 |
| 3 | Resistance to Dust, Solid Objects and Moisture | IS 10322 (Part 5/Sec 7) Cl. 20.14 |
How IS 10322 testing works
- Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.
Need the ISI mark or CRS registration as well? See IS 10322 BIS certification for the products covered, the order, fees and process.
Frequently asked questions
Which IS 10322 tests are NABL accredited?
All 52 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 10322 shown next to it. The report carries the NABL accreditation mark for these tests.
Can the IS 10322 test report be used for BIS certification?
Yes. Testing to IS 10322 is available at a BIS-recognised laboratory, so the report can be submitted with a BIS application. BIS may still draw its own samples during the factory inspection.
How many samples are needed for IS 10322 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IS 10322?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other LED lamp & luminaire testing
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- LED Lamp & Luminaire Testing 144 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 225 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.