Skip to content
NABL accredited testing

IS 10322 Testing: Luminaires

NABL accredited testing of luminaires to IS 10322: 52 tests, each against its clause. Testing is available at a BIS-recognised laboratory, so the report can be used for BIS certification.

StandardIS 10322 · BIS certification under IS 10322
CoversFixed General Purpose Luminaries; Hand Lamps; Rope Lights; Lighting Chain; Lighting Chains
Accredited tests52
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAvailable
CategoryLED Lamp & Luminaire Testing

IS 10322 tests we offer

Fixed General Purpose Luminaries

#TestClause / method
1Classification of LuminariesIS 10322 (Part 5/Sec 1) Cl. 5
2ConstructionIS 10322 (Part 5/Sec 1) Cl. 7
3Creepage Distance and ClearanceIS 10322 (Part 5/Sec 1) Cl. 8
4Endurance Test and Thermal TestIS 10322 (Part 5/Sec 1) Cl. 13
5External And Internal WiringIS 10322 (Part 5/Sec 1) Cl. 11
6GENERAL TEST REQUIREMENTSIS 10322 (Part 5/Sec 1) Cl. 4
7Insulation Resistance and Electric StrengthIS 10322 (Part 5/Sec 1) Cl. 15
8MarkingIS 10322 (Part 5/Sec 1) Cl. 6
9Protection Against Electric ShockIS 10322 (Part 5/Sec 1) Cl. 12
10Provision for EarthingIS 10322 (Part 5/Sec 1) Cl. 9
11Resistance to dust and moistureIS 10322 (Part 5/Sec 1) Cl. 14
12Resistance to Heat, Fire and TrackingIS 10322 (Part 5/Sec 1) Cl. 16
13TerminalsIS 10322 (Part 5/Sec 1) Cl. 10

Hand Lamps

#TestClause / method
1Classification of LuminariesIS 10322 (Part 5/Sec 6) Cl. 5
2Creepage Distance and ClearanceIS 10322 (Part 5/Sec 6) Cl. 8
3Endurance Test and Thermal TestIS 10322 (Part 5/Sec 6) Cl. 13
4External And Internal WiringIS 10322 (Part 5/Sec 6) Cl. 11
5Insulation Resistance and Electric StrengthIS 10322 (Part 5/Sec 6) Cl. 15
6MarkingIS 10322 (Part 5/Sec 6) Cl. 6
7Protection Against Electric ShockIS 10322 (Part 5/Sec 6) Cl. 12
8Provision for EarthingIS 10322 (Part 5/Sec 6) Cl. 9
9Resistance to dust and moistureIS 10322 (Part 5/Sec 6) Cl. 14
10Resistance to Heat, Fire and TrackingIS 10322 (Part 5/Sec 6) Cl. 16
11TerminalsIS 10322 (Part 5/Sec 6) Cl. 10
12ConstructionIS 10322 (Part 5/Sec 6) Cl. 7
13General Test RequirementsIS 10322 (Part 5/Sec 6) Cl. 5

Rope Lights

#TestClause / method
1Classification of LuminariesIS 10322 (Part5/Sec 9) Cl. 21.5
2ConstructionIS 10322 (Part5/Sec 9) Cl. 21.7
3Creepage Distance and ClearanceIS 10322 (Part5/Sec 9) Cl. 21.8
4Endurance Test and Thermal TestIS 10322 (Part5/Sec 9) Cl. 21.13
5External And Internal WiringIS 10322 (Part5/Sec 9) Cl. 21.11
6General test requirementsIS 10322 (Part5/Sec 9) Cl. 21.4
7Insulation Resistance and Electric StrengthIS 10322 (Part5/Sec 9) Cl. 21.15
8MarkingIS 10322 (Part5/Sec 9) Cl. 21.6
9Protection Against Electric ShockIS 10322 (Part5/Sec 9) Cl. 21.12
10Resistance to Dust, Solid Objects and MoistureIS 10322 (Part5/Sec 9) Cl. 21.14
11Resistance to Heat, Fire and TrackingIS 10322 (Part5/Sec 9) Cl. 21.16
12TerminalsIS 10322 (Part5/Sec 9) Cl. 21.10
13Test for Interconnecting Connector for use in Lighting chainIS 10322 (Part5/Sec 9) Annex A.16

Lighting Chain

#TestClause / method
1Classification of LuminariesIS 10322 (Part 5/Sec 7) Cl. 20.5
2Creepage Distance and ClearanceIS 10322 (Part 5/Sec 7) Cl. 20.8
3Endurance Test and Thermal TestIS 10322 (Part 5/Sec 7) Cl. 20.13
4External And Internal WiringIS 10322 (Part 5/Sec 7) Cl. 20.11
5Insulation Resistance and Electric StrengthIS 10322 (Part 5/Sec 7) Cl. 20.15
6MarkingIS 10322 (Part 5/Sec 7) Cl. 20.6
7Protection Against Electric ShockIS 10322 (Part 5/Sec 7) Cl. 20.12
8Resistance to Heat, Fire and TrackingIS 10322 (Part 5/Sec 7) Cl. 20.16
9TerminalsIS 10322 (Part5/Sec 7) Cl. 20.10
10Test for Interconnecting Connector for use in Lighting chainIS 10322 (Part 5/Sec 7) Annex A.16

Lighting Chains

#TestClause / method
1ConstructionIS 10322 (Part 5/Sec 7) Cl. 20.7
2General test requirementsIS 10322 (Part 5/Sec 7) Cl. 20.4
3Resistance to Dust, Solid Objects and MoistureIS 10322 (Part 5/Sec 7) Cl. 20.14

How IS 10322 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Need the ISI mark or CRS registration as well? See IS 10322 BIS certification for the products covered, the order, fees and process.

Frequently asked questions

Which IS 10322 tests are NABL accredited?

All 52 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 10322 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 10322 test report be used for BIS certification?

Yes. Testing to IS 10322 is available at a BIS-recognised laboratory, so the report can be submitted with a BIS application. BIS may still draw its own samples during the factory inspection.

How many samples are needed for IS 10322 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 10322?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other LED lamp & luminaire testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote