IS 7098 Testing: XLPE Insulated Cables

NABL accredited testing of XLPE insulated cables to IS 7098: 86 tests, each against its clause. Testing is available at a BIS-recognised laboratory, so the report can be used for BIS certification.

StandardIS 7098 · BIS certification under IS 7098
CoversCross Linked Polyethylene Insulated, PVC sheathed cables for working voltages up to and Including 1100 volts; Cross Linked Polyethylene Insulated Thermoplastic Sheathed cables for working voltages from 3.3 kV up to and including 33kV; Cross Linked Polyethylene Insulated, Thermoplastic sheathed cables Working voltage up to and including 1100 Volts; Cross Linked Polyethylene Insulated, Thermoplastic sheathed cables For Working voltage up to and including 1100 Volts
Accredited tests86
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAvailable
CategoryCable & Wire Testing

IS 7098 tests we offer

Cross Linked Polyethylene Insulated, PVC sheathed cables for working voltages up to and Including 1100 volts

#TestClause / method
1Oxygen Index TestCl.15.1.1(C1)-a Cl.16.4 of IS 7098 (Pt- 1),ASTM D 2863-9
2Halogen Acid GasCl.15.1.1(C2)-f Cl.16.13, 16.8 of IS 7098 (Pt-1),IS10810(Pt-59)
3Cold Impact TestCl. 15.4(b) of IS 7098(Pt-1), Cl. 4.1,(Table-2) of IS 5831,IS 10810 (Pt 21)
4Armour Resistance TestCl. 15.1(b) Cl. 13.6(g) of IS 7098 (Pt-1),Cl. 8.4 of IS3975,IS 10810 (Pt 42)
5Flame retardance test onbunched cablesCl. 15.1.1(C1)-c Cl.16.6 of IS 7098 (Pt- 1),IEC-60332-3-22/23/24
6Flame Retardance Teston Single CableCl. 15.1.1(C1)-b Cl.16.5 of IS 7098 (Pt- 1),SS-424-1475
7Tensile strength of insulation & SheathCl. 15.1(d),(e)-i of IS7098(Pt-1),Cl. 4.1 (table-1,2) of IS 5831,IS 10810 (Pt 7)
8Thickness of Insulation & SheathCl. 15.1(C) Cl. 9.2,12.3, 14.3.1 (Table- 3,5,8) of IS 7098 (Pt-1),IS 10810 (Pt 6)
9Torsion test on Galvanized steel wire for armouringCl. 15.1(b) Cl. 13.6(c)of IS 7098(Pt-1),Cl. 8.2 of Table 6 of IS3975,IS 10810 (Pt 38)
10Mass of Zinc coatingCl. 15.1(b) Cl.13.6 (f)of IS 7098(Pt-1), Cl. 9.1 of IS 3975,IS 10810 (Pt 41)
11Tensile strength for Aluminium ConductorCl. 15.1(a)- i) of IS7098(Pt-1),Cl. 7.2.1. of IS 8130,IS 10810(Pt 2)
12Smoke DensityCl. 15.1.1(C2)-e Cl.16.10 of IS 7098 (Pt-1),IS 10810 (Pt- 63), ASTM D 2843
13Halogen Aicd GasCl. 15.1.1(C2)-f Cl.16.13, 16.8 of IS 7098 (Pt-1),IEC-60754-1
14Shrinkage testCl. 15.1(d),(e)- iv,vi Cl.4.1(Table-1,2) of IS 7098(Pt-1),IS 10810(Pt 12)
15Annealing test for Copper ConductorCl. 15.1(a)-i) of IS7098(Pt-1),Cl. 7.1.2.1, 7.2.3 of IS8130,IS 10810 (Pt 1)
16Dimension for armouring materialCl.15.1(b) Cl.13.6(a), (b) of IS 7098(Pt- 1),Cl.7 of IS 3975,IS 10810 (Pt 36)
17Insulation resistance (Volume Resistivity)Cl. 15.1(f) Cl.4.1 (table-1) of IS 7098(Pt-1),IS 10810 (Pt 43)
18Temperature Index TestCl. 15.1.1(C2)-g Cl.16.9 of IS 7098(Pt- 1),ASTM D 2863-09
19Uniformity of Zinc coatingCl. 15.1(b) Cl. 13.6(e) of IS 7098(Pt-1),Cl. 9.2 of IS3975,IS 10810 (Pt40)
20Water Absorption (Gravimetric)Cl. 15.1(d)-v Cl. 4.1(Table-1) of IS 7098(Pt-1),IS 10810(Pt 33)
21Heat shock testCl. 15.1(e)-vi of IS7098(Pt-1),Cl. 4.1(Table-2) of IS5831,IS 10810 (Pt 14)
22Ageing in air oven- ElongationCl. 15.1(d),(e)- i Cl.4.1,(table-1,2),IS 7098(Pt-1),IS 10810(Pt 11)
23Ageing in air oven- Tensile StrengthCl. 15.1(d),(e)- i Cl.4.1,(table-1,2), IS 7098(Pt-1),IS 10810(Pt 11)
24Elongation at break of armouring materialCl. 15.1(b) Cl.13.6(a),(b) of IS 7098(Pt-1),IS 10810 (Pt 37)
25Elongation at break of insulationCl. 15.1(d),(e)-i Cl.4.1 (table-1,2) of IS 7098(Pt-1),IS 10810 (Pt 7)
26Flame retardance test on bunched cablesCl. 15.1.1(C1)-c Cl.16.6 of IS 7098 (Pt- 1),IS 10810 (Pt -62)
27Tensile strength of armouring materialCl. 15.1(b) Cl.13.6(a),(b) of IS 7098(Pt- 1),IS 10810 (Pt 37)
28Winding test on Galvanized steel strips for armouringCl. 15.1(b) Cl. 13.6(d) of IS 7098(Pt- 1),IS 10810 (Pt 39
29Flammability test (unaffected portion/ under period of Burning)Cl. 15.1(h) Cl.16.3 of IS 7098(Pt-1),IS 10810 (Pt 53)
30Hot Set Test (Elongation under load & permanent elongation)Cl. 15.1(d)- i Cl. 4.1(Table-1) of IS 7098(Pt-1),IS 10810 (Pt 30)
31Resistivity & Conductance test of Armour (Wires/strips)Cl. 15.1(b) Cl. 13.6(g) of IS 7098(Pt-1),Cl. 8.4 of IS 3975,IS10810 (Pt 42)
32Conductor resistanceCl. 15.1(a)-iv) of IS7098(Pt-1),Cl. 7.3 (Table-1,2) of IS 8130,IS 10810 (Pt 5)
33Wrapping test for Aluminium ConductorCl. 15.1(a)- i) of IS7098(Pt-1),Cl.7.2.2 of IS 8130,IS 10810 (Pt 3)
34Cold Bend TestCl.15.4(a) of IS 7098(Pt-1),Cl. 4.1,(Table- 2) of IS 5831,IS10810 (Pt 20

Cross Linked Polyethylene Insulated Thermoplastic Sheathed cables for working voltages from 3.3 kV up to and including 33kV

#TestClause / method
1Annealing test (for Copper)IS 7098 (Part 2) Cl. 19.1
2Armoured Coverage PercentageIS 7098 ( Part 2) Cl. 17.2 & Annex F
3Carbon Black ContentIS 7098 (Part 2)
4Cold Bend TestIS 7098 (Part 2)
5Cold Impact TestIS 7098 (Part 2) Cl 19.4
6Conductor Resistance Test / Resistance of ConductorsIS 7098 (Part 2)
7Determination of the halogen acid gas contentIS 7098 (Part 2) Cl 20.13
8Dimensions of Armouring MaterialIS 7098 (Part 2) Cl 17.3 & Table 6
9Flame Retardance test on Bunched CablesIS 7098 ( Part 2) Cl 20.12
10Flame Retardance test on single CablesIS 7098 ( Part 2)
11Flammability TestIS 7098 (Part 2) Cl 20.8
12Heat Shock Test on SheathIS 7098 (Part 2) Cl 19.1
13High Voltage TestIS 7098 (Part 2) Cl 20.7
14Hot Deformation/ Pressure Test at High Temperature on SheathIS 7098 (Part 2) Table 3 & Cl 19.1
15Hot Set TestIS 7098 (Part 2) Table 1 & Cl 19.1
16Loss of Mass in Air OvenIS 7098 (Part 2) Cl 19.1
17Mass of Zinc CoatingIS 7098 ( Part 2) Cl 19.1
18Measurement of Temperature IndexIS 7098 (Part 2) Cl 20.15
19Oxygen Index TestIS 7098 (Part 2) Cl 20.10
20Resistivity Test of semiconducting screenIS 7098 ( Part 2) Cl 20.9 & Annex. E
21Shrinkage Test on Insulation & SheathIS 7098 (Part 2) Table 1 & Cl 19.1
22Smoke Density RatingIS 7098 (Part 2) Cl 20.14
23Tensile strength & Elongation at break for armouring materialIS 7098 ( Part 2) Cl 19.1
24Tensile Strength & Elongation at Break on Insulation & SheathIS 7098 (Part 2) Table 1 & 3 Cl. 19.1
25Tensile Test (for Aluminium)IS 7098 (Part 2) Cl. 19.1
26Test for overall dimensions, Eccentricity & thickness of Insulation & SheathIS 7098 (Part 2) Cl. 19.1, Table 4,5 & 7 Annex. A
27Thermal Stability Test on SheathIS 7098 (Part 2) Cl. 19.1
28Torsion Test for Round WireIS 7098 ( Part 2) Cl. 19.1
29Uniformity of Zinc CoatingIS 7098 ( Part 2) Cl. 19.1
30Volume ResistivityIS 7098 (Part 2) Table 1 & Cl 19.1
31Water Absorption (Gravimetric)IS 7098 (Part 2) Table 1 & Cl 19.1
32Winding Test for Formed WireIS 7098 ( Part 2) Cl. 19.1
33Wrapping Test (for Aluminium)IS 7098 (Part 2) Cl. 19.1

Cross Linked Polyethylene Insulated, Thermoplastic sheathed cables Working voltage up to and including 1100 Volts

#TestClause / method
1Cold elongation test for LSHF sheathCl.16.1 of IS7098(Pt.1) & IS:10810 (Pt.7):1984
2Cold Impact TestCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.21): 1984
3Elongation at break for LSHF sheathCl.16.1 of IS7098(Pt.1) & IS 10810(Pt.7): 1984
4Elongation at break for PE sheathCl.16.1 of IS7098(Pt.1) & IS 10810(Pt.7): 1984
5Hot deformation test for LSHF sheathCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.15): 1984
6Shrinkage test sheath for LSHF sheathCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.12): 1984
7Shrinkage test sheath for PE sheathCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.12): 1984
8Smoke DensityCl.16.1 of IS7098(Pt.1) & IS 13360 (Pt. 6/Sec 9):2025 & ASTM D 2843:1999
9Tensile strength for PE sheathCl.16.1 of IS7098(Pt.1) & IS 10810(Pt.7): 1984
10Test for Conductivity (Cat. C)Cl.16.1 of IS7098(Pt.1):2025
11Test for Light transmission (Cat. C)Cl.16.1 of IS7098(Pt.1) & IS 10810 (Pt 63):1993
12Water Absorption LSHF sheathCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.33): 1984
13Cold Bend TestCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.20): 1984
14Armour Coverage PercentageIS 7098(Pt.1):2025& Appendix- C
15Carbon black Content for PE sheathCl.16.1 of IS 7098(Pt.1) &IS 10810(Pt.32): 1984
16Hot deformation test for PE sheathCl.16.1 of IS7098(Pt.1) & IS:10810(Pt.15): 1984
17Tensile strength for LSHF sheathCl.16.1 of IS7098(Pt.1) & IS 10810(Pt.7): 1984
18Test for pH (Cat. C)Cl.16.1 of IS7098(Pt.1)

Cross Linked Polyethylene Insulated, Thermoplastic sheathed cables For Working voltage up to and including 1100 Volts

#TestClause / method
1Armoured Coverage PercentageIS 7098 ( Part 1) Cl.13.1.2 & Appendix C

How IS 7098 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Need the ISI mark or CRS registration as well? See IS 7098 BIS certification for the products covered, the order, fees and process.

Frequently asked questions

Which IS 7098 tests are NABL accredited?

All 86 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 7098 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 7098 test report be used for BIS certification?

Yes. Testing to IS 7098 is available at a BIS-recognised laboratory, so the report can be submitted with a BIS application. BIS may still draw its own samples during the factory inspection.

How many samples are needed for IS 7098 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 7098?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other cable & wire testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote