NABL accredited testing of conductors for insulated cables to IS 8130: 31 tests, each against its clause.

StandardIS 8130
CoversHalogen Free Flame Retardant (HFFR) cables; Elastomer insulated Cables for working voltages up to and including 1100 volts; PVC Insulated Cables; Aerial Bunched Cables; Cross Linked Polyethylene Insulated, PVC sheathed cables for working voltages up to and Including 1100 volts; PVC insulated (heavy duty) Electric cables For Working voltages up to and including 1100 Volts; Welding Cables; Elastomer Insulated Cables with Limited Circuit Integrity when Affected by Fire; PVC Insulated (Heavy Duty) Electric cables for working voltages from 3.3 kV up to and including 11kV
Accredited tests31
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAsk us which laboratory your BIS scheme accepts
CategoryCable & Wire Testing

IS 8130 tests we offer

Halogen Free Flame Retardant (HFFR) cables

#TestClause / method
1Tensile strength for Aluminium ConductorTable-2, III).a).iv),Cl. 4.1 of IS 17048, Cl. 7.2.1 a,b of IS 8130, IS 10810 (Pt 2)
2Annealing test for Copper ConductorTable-2, III).a). i),Cl. 4.1 of IS 17048, Cl. 7.1.2.1 & 7.2.3 of IS 8130, IS 10810 (Pt 1)
3Conductor resistanceTable-2, III).a).i, Cl. 4.1 of IS 17048, Cl. 7.3 of IS 8130, IS 10810 (Pt 5)
4Persulphate test for tinned copperTable-2, III).a). i),Cl. 5.10 of IS 17048, Cl. 7.1.1 of IS 8130, IS 10810 (Pt -4)
5Wrapping test for Aluminium ConductorTable-2, III).a).v),Cl. 4.1 of IS 17048, Cl. 7.2.2 of IS 8130, IS 10810 (Pt 3)

Elastomer insulated Cables for working voltages up to and including 1100 volts

#TestClause / method
1Annealing test for Copper ConductorCl. 21.1, of IS 9968(Pt-1), Cl.7.1.2, 7.2.3 of IS 8130,IS 10810 (Pt 1)
2Persulphate test ( for tinned Copper Conductor)Cl. 21.1 Cl.3 of IS 9968(Pt-1),Cl.7.1.1of IS 8130,IS 10810 (Pt -4)
3Tensile strength for Aluminium ConductorCl. 21.1,Cl.3 of IS9968(Pt-1),Cl.7.2.1 a&b of IS 8130,IS10810 (Pt 2)
4Wrapping test for Aluminium ConductorCl. 21.1, Cl.3 of IS9968(Pt-1),Cl.7.2.2of IS 8130,IS 10810 (Pt 3)
5Conductor resistanceCl. 21.1(d) of IS 9968(Pt-1), Cl. 4.1 (Table- 2,3) of IS 8130, IS10810 (Pt 5)

PVC Insulated Cables

#TestClause / method
1Annealing test for Copper ConductorTable-1, i).a).1),Cl.4.1 of IS 694,Cl. 7.1.2.1,7.2.3 of IS 8130,IS 10810 (Pt 1)
2Persulphate test ( for tinned Copper Conductor)Table-1, i).a).5),Cl.10.11 of IS 694,Cl. 7.1.1 of IS 8130,IS10810 (Pt-4)
3Tensile strength for Aluminium ConductorTable-1, i).a).2), Cl.4.1 of IS 694,Cl. 4.1, 7.2.1 a, b of IS 8130,IS 10810 (Pt 2)
4Conductor resistanceTable-1, i).a).4),Cl.4.2 of IS 694,Cl. 7.3 of IS 8130,IS 10810(Pt 5)

Aerial Bunched Cables

#TestClause / method
1Wrapping testCl. 10.1(a)- i of IS 14255, Cl.7.2.2 of IS 8130,IS 10810 (Pt 3)
2Test on Messenger Conductor-Conductor resistanceCl.10.1(a)- i of IS 14255, Cl. 6 (Table- 3) of IS 8130,IS 10810 (Pt 5)
3Conductor resistanceCl.10.1(a)- i of IS 14255,Cl. 7.3 (Table- 1,2) of IS 8130,IS 10810 (Pt 5)
4Tensile strength of aluminium conductorCl. 10.1(a)-i of IS 14255,Cl. 7.2.1. of IS 8130,IS 10810 (Pt 2)

Cross Linked Polyethylene Insulated, PVC sheathed cables for working voltages up to and Including 1100 volts

#TestClause / method
1Tensile strength for Aluminium ConductorCl. 15.1(a)- i) of IS7098(Pt-1),Cl. 7.2.1. of IS 8130,IS 10810(Pt 2)
2Annealing test for Copper ConductorCl. 15.1(a)-i) of IS7098(Pt-1),Cl. 7.1.2.1, 7.2.3 of IS8130,IS 10810 (Pt 1)
3Conductor resistanceCl. 15.1(a)-iv) of IS7098(Pt-1),Cl. 7.3 (Table-1,2) of IS 8130,IS 10810 (Pt 5)
4Wrapping test for Aluminium ConductorCl. 15.1(a)- i) of IS7098(Pt-1),Cl.7.2.2 of IS 8130,IS 10810 (Pt 3)

PVC insulated (heavy duty) Electric cables For Working voltages up to and including 1100 Volts

#TestClause / method
1Wrapping test for Aluminium ConductorCl.15.1(a)-3) of IS1554(Pt-1), Cl.7.2.2of IS 8130,IS 10810(Pt 3)
2Conductor resistanceCl. 15.1(a)-4) of IS1554(Pt-1),Cl. 7.3, (Table-1,2) of IS 8130,IS 10810 (Pt 5)
3Annealing test for Copper ConductorCl. 15.1(a)-1) of IS1554(Pt-1),Cl. 7.1.2.1 of IS 8130,IS10810 (Pt 1)
4Tensile strength for Aluminium ConductorCl. 15.1(a)-2) of IS1554(Pt-1), Cl. 7.2.1.of IS 8130,IS10810 (Pt 2)

Welding Cables

#TestClause / method
1AnnealingtestCl. 10.1.a.1, Cl.7 of IS9857,Cl.7.1.2, 7.2.3 of IS 8130,IS 10810(Pt 1)
2ConductorresistanceCl. 10.1.a.2 of IS 9857,Cl. 7.3 (Table- 3,4,5) of IS 8130,IS10810 (Pt 5)

Elastomer Insulated Cables with Limited Circuit Integrity when Affected by Fire

#TestClause / method
1Annealing test (for copper)IS 16246 Cl.3.2 & 17.1 Table No.1 & IS 8130
2Conductor Resistance testIS 16246 Cl.3.2 &17.1 Table No.1 IS 8130

PVC Insulated (Heavy Duty) Electric cables for working voltages from 3.3 kV up to and including 11kV

#TestClause / method
1Annealing test (for Copper)IS 1554 (Part 2) Cl.18.1 & IS 8130

How IS 8130 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IS 8130 tests are NABL accredited?

All 31 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 8130 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 8130 test report be used for BIS certification?

BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.

How many samples are needed for IS 8130 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 8130?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.