IS 16246 Testing: Fire Resistant Circuit Integrity Cables
NABL accredited testing of fire resistant circuit integrity cables to IS 16246: 32 tests, each against its clause.
| Standard | IS 16246 |
|---|---|
| Covers | Elastomer Insulated Cables with Limited Circuit Integrity when Affected by Fire |
| Accredited tests | 32 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| BIS-recognised testing | Ask us which laboratory your BIS scheme accepts |
| Category | Cable & Wire Testing |
IS 16246 tests we offer
| # | Test | Clause / method |
|---|---|---|
| 1 | Water absorption test (7 – 14 days-% Increase in Capacitance) (for insulation as applicable) | IS 16246: Cl.3.2&17.1, IS 6380 |
| 2 | Ageing in Air Bomb- Elongation at Break (Insulation, Inner Sheath & Outer sheath) | IS 16246 Cl.3.2 & 17.1& Table No.1 & 2, IS 6380 |
| 3 | Ageing in Air Bomb- Tensile Strength (Insulation, Inner Sheath & Outer sheath) | IS 16246 Cl.3.2 & 17.1 & Table No.1 & 2, IS 6380 |
| 4 | Ageing in air oven Elongation at Break Variation (Insulation & Sheath) | IS 16246 Cl.3.2 & 17.1 & Table No.1 |
| 5 | Ageing in air oven Tensile Strength Variation (Insulation & Sheath) | IS 16246 Cl.3.2 & 17.1 & Table No.1 |
| 6 | Annealing test (for copper) | IS 16246 Cl.3.2 & 17.1 Table No.1 & IS 8130 |
| 7 | Circuit integrity test under fire condition | IS 16246 Cl.3.2 & 17.1 Table No.1 Cl.18.3 |
| 8 | Conductor Resistance test | IS 16246 Cl.3.2 &17.1 Table No.1 IS 8130 |
| 9 | Dimensions of armouring wires (Round & formed wires) | IS 16246 Cl.3.2 & 17.1, Cl.8,15 & Table No.1,6 |
| 10 | Elongation at break (Insulation, Inner sheath & Outer Sheath) | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl.9.1 & 9.2 Table No 2 |
| 11 | Elongation at break of armouring material (round wire & formed wire) | IS 16246 Cl.3.2 &17.1, Cl.8 & Table No.1,6 |
| 12 | Flame Retardance test on Bunched Cables | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl.18.4.2 |
| 13 | Flame Retardance test on Single Cable | IS 16246 Cl. 3.2 & 17.1 Table No.1 & Cl. 18.4.1 |
| 14 | High Voltage test | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl.18.2 |
| 15 | Hot set test –Elongation Under Load (Insulation, Inner sheath & outer sheath) | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl. 9.1& 9.2, Table No 2 |
| 16 | Hot set test-Permanent Elongation (Insulation, Inner sheath & outer sheath) | IS 16246 Cl. 3.2 & 17.1 Table No.1 & Cl. 9.1 & 9.2, Table No 2 |
| 17 | Insulation resistance | IS 16246 Cl. 3.2 & 17.1 Table No.1 & IS 6380:1984 |
| 18 | Mass of zinc coating (for round & formed wire) | IS 16246 Cl.3.2 & 17.1, Cl.8,15 & Table No.1,6 |
| 19 | Oil Resistance test (Inner sheath & Outer sheath) | IS 16246 Cl. 3.2 & 17.1 Table No.1 & Cl.9.1 & 9.2, Table No 2 |
| 20 | Oxygen Index test (Inner sheath & Outer sheath) | IS 16246 Cl. 3.2 & 17.1 Table No.1 & Cl. 9.1 & 9.2,Table No 2 |
| 21 | Persulphate test (for tinned copper conductor) | IS 16246 Cl.3.2&17.1 Table No.1 |
| 22 | Resistivity test of armour (for round & formed wire) | IS 16246 Cl.3.2 & 17.1,Cl.8,15 & Table No.1,6 |
| 23 | Tensile Strength &of armouring material (round wire & formed wire) | IS 16246 Cl.3.2 &17.1, Cl.8 & Table No.1,6 |
| 24 | Tensile strength (Insulation, Inner sheath & Outer Sheath) | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl. 9.1 & 9.2,Table No 2 IS: 6380 |
| 25 | Test for smoke density rating (Inner sheath & Outer sheath) | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl. 9.1 & 9.2, Table No 2 |
| 26 | Test for Temperature Index (Inner sheath & Outer sheath) | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl.9.1 & 9.2,Table No 2 |
| 27 | Test for thickness of Insulation, Inner sheath and outer Sheath | IS 16246 Cl.3.2 & 17.1 Table No.1 & Cl.9.1 & 9.2,Table No 2 |
| 28 | Thickness of Tape (Glass Tape/ PETP Tape) | IS 16246 Cl.6 |
| 29 | Torsion test of armouring wire (for round wire) | IS 16246 Cl.3.2 & 17.1,Cl. 8, 15 & Table No.1,6 |
| 30 | Uniformity of zinc coating (for round & formed wire) | IS 16246: Cl.3.2 & 17.1, Cl.8,15 & Table No.1,6 |
| 31 | Water absorption test (1 – 14 days-% Increase in Capacitance) (for insulation as applicable) | IS 16246 Cl.3.2&17.1, IS 6380 |
| 32 | Winding test of armouring wire (for formed wire) | IS 16246 Cl.3.2 & 17.1, Cl.8,15 & Table No.1,6 |
How IS 16246 testing works
- Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.
Frequently asked questions
Which IS 16246 tests are NABL accredited?
All 32 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 16246 shown next to it. The report carries the NABL accreditation mark for these tests.
Can the IS 16246 test report be used for BIS certification?
BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.
How many samples are needed for IS 16246 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IS 16246?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other cable & wire testing
- IS 10810 Methods of Test for Cables
- IS 7098 XLPE Insulated Cables
- IS 1554 PVC Insulated Heavy Duty Cables
- IS 9968 Elastomer Insulated Cables
- IS 17505 Fire Survival Cables
- IS 6380 Elastomeric Insulation & Sheath for Cables
- IS 5831 PVC Insulation & Sheath for Cables
- IS 4289 Flexible Lift Cables
- IS 8130 Conductors for Insulated Cables
- IS 17293 Solar PV Cables
- IS 14494 Flexible Mining Cables
- IS 17048 HFFR Cables
- IS 694 PVC Insulated Cables
- IS 2465 Cables for Motor Vehicles
- IS 3975 Steel Armour Wires & Tapes for Cables
- IS 14255 Aerial Bunched Cables
- IS 9857 Welding Cables
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- LED Lamp & Luminaire Testing 144 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 225 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.