Skip to content
NABL accredited testing

IS 16046 Testing: Portable Lithium & Nickel Cells and Batteries

NABL accredited testing of portable lithium & nickel cells and batteries to IS 16046: 53 tests, each against its clause.

StandardIS 16046 · BIS certification under IS 16046
CoversSecondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Nickel); Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Lithium)
Accredited tests53
AccreditationNABL, ISO/IEC 17025:2017
BIS-recognised testingAsk us which laboratory your BIS scheme accepts
CategoryBattery & Cell Testing

IS 16046 tests we offer

Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Nickel)

#TestClause / method
1Assembly of cells into batteriesCl. No. 5.6 IS 16046-1
2Case stress at high temperature (batteries)Cl. No. 7.2.3 IS 16046-1
3Charging procedure for test purposeCl. No.7.1 IS 16046-1
4Continuous low-rate charging (Cell)Cl. No. 7.2.1 IS 16046-1
5Crushing of cellsCl. No. 7.3.6 IS 16046-1
6External short circuitCl. No. 7.3.2 IS 16046-1
7Forced Discharge (Cells)Cl.No.7.3.9 IS 16046-1
8Free FallCl. No. 7.3.3 IS 16046-1
9General Safety ConsiderationCl. No. 5.1 IS 16046-1
10Incorrect installation (cells)Cl. No. 7.3.1 IS 16046-1
11Information for safetyCl. No. 8 IS 16046-1
12Insulation and wiringCl. No. 5.2 IS 16046-1
13Low pressureCl. No. 7.3.7 IS 16046-1
14Mechanical shock(Crash hazard)Cl. No. 7.3.4 IS 16046-1
15OverchargeCl. No. 7.3.8 IS 16046-1
16PackagingCl. No. 10 IS 16046-1
17Parameter measurement ToleranceIS 16046 (Part-1) Cl. 4
18Quality planIS 16046 (Part -1) Cl. 5.7
19Small Cell and Battery safety InformationIS 16046 (Part -1) Cl. 8.2
20Temperature cyclingCl. No. 7.2.4 IS 16046-1
21Temperature, voltage and current managementCl. No. 5.4 IS 16046-1
22Terminal contactsCl. No. 5.5 IS 16046-1
23Thermal Abuse(Cells)Cl. No. 7.3.5 IS 16046-1
24Type test and Sample SizeIS 16046 (Part 1) Cl. 6
25VentingCl. No. 5.3 IS 16046-1
26Verification of MarkingCl. No. 9 IS 16046-1
27VibrationCl. No. 7.2.2 IS 16046-1

Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Lithium)

#TestClause / method
1Assembly of cells into batteriesCl. No. 5.6 IS 16046-2
2Battery safety componentIS 16046 (Part -2) Cl. 5.8
3Case stress at high ambient temperature(Battery)Cl. No. 7.2.2 IS 16046-2
4Charging procedure for test purposeCl. No.7.1 IS 16046-2
5Continuous charging at constant voltage (Cells)Cl. No. 7.2.1 IS 16046-2
6Crush (cells)Cl. No. 7.3.5 IS 16046-2
7External short circuit (cells)Cl. No. 7.3.1 IS 16046-2
8External short circuit(Battery)Cl. No. 7.3.2 IS 16046-2
9Forced Discharge(Cells)Cl. No. 7.3.7 IS 16046-2
10Free FallCl. No. 7.3.3 IS 16046-2
11General Safety ConsiderationCl. No. 5.1 IS 16046-2
12Information for safetyIS 16046 (Part -2) Cl. 8, 8.1, 8.2
13Insulation and wiringCl. No. 5.2 IS 16046-2
14Measurement of the internal AC resistance for coin cells (Annex. D)IS 16046-2 Annex. D
15Mechanical Shock (Battery)Cl. 7.3.8.2 IS 16046 (Part -2)
16Over-charging of batteryCl. No. 7.3.6 IS 16046-2
17Packaging and transportCl. No. 10 IS 16046-2
18Parameter measurement ToleranceIS 16046 (Part- 2) Cl.4
19Quality planIS 16046 (Part -2) Cl. 5.7
20Temperature, voltage and current managementCl. No. 5.4 IS 16046-2
21Terminal contactsCl. No. 5.5 IS 16046-2
22Thermal Abuse(Cells)Cl. No. 7.3.4 IS 16046-2
23Type test and sample sizeIS 16046 (Part- 2) Cl.6
24VentingCl. No. 5.3 IS 16046-2
25Verification of MarkingCl. No. 9 IS 16046-2
26VibrationCl. No. 7.3.8.1 IS 16046-2

How IS 16046 testing works

  1. Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.

Need the ISI mark or CRS registration as well? See IS 16046 BIS certification for the products covered, the order, fees and process.

Frequently asked questions

Which IS 16046 tests are NABL accredited?

All 53 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 16046 shown next to it. The report carries the NABL accreditation mark for these tests.

Can the IS 16046 test report be used for BIS certification?

BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.

How many samples are needed for IS 16046 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IS 16046?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other battery & cell testing

  • IS 16893 EV Lithium-ion Cells
  • IS 14257 High Cranking Automotive Lead-Acid Batteries
  • IS 16270 Solar PV Batteries
  • IS 7372 Automotive Lead-Acid Batteries
  • IS 16805 Industrial Lithium Batteries (Safety)
  • IS 16822 Industrial Lithium Batteries (Performance)
  • IS 1651 Stationary Tubular Lead-Acid Batteries
  • IS 8320 Lead-Acid Storage Batteries
  • IS 16047 Portable Lithium Cells (Performance)
  • IS 1652 Stationary Planté Lead-Acid Batteries
  • IS 13369 Tubular Monobloc Stationary Batteries
  • IS 13514 Lead-Acid Batteries for Electric Road Vehicles
  • IS 15549 Stationary VRLA Batteries
  • IS 5154 Lead-Acid Traction Batteries

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote