IS 16046 Testing: Portable Lithium & Nickel Cells and Batteries
NABL accredited testing of portable lithium & nickel cells and batteries to IS 16046: 53 tests, each against its clause.
| Standard | IS 16046 · BIS certification under IS 16046 |
|---|---|
| Covers | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Nickel); Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Lithium) |
| Accredited tests | 53 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| BIS-recognised testing | Ask us which laboratory your BIS scheme accepts |
| Category | Battery & Cell Testing |
IS 16046 tests we offer
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Nickel)
| # | Test | Clause / method |
|---|---|---|
| 1 | Assembly of cells into batteries | Cl. No. 5.6 IS 16046-1 |
| 2 | Case stress at high temperature (batteries) | Cl. No. 7.2.3 IS 16046-1 |
| 3 | Charging procedure for test purpose | Cl. No.7.1 IS 16046-1 |
| 4 | Continuous low-rate charging (Cell) | Cl. No. 7.2.1 IS 16046-1 |
| 5 | Crushing of cells | Cl. No. 7.3.6 IS 16046-1 |
| 6 | External short circuit | Cl. No. 7.3.2 IS 16046-1 |
| 7 | Forced Discharge (Cells) | Cl.No.7.3.9 IS 16046-1 |
| 8 | Free Fall | Cl. No. 7.3.3 IS 16046-1 |
| 9 | General Safety Consideration | Cl. No. 5.1 IS 16046-1 |
| 10 | Incorrect installation (cells) | Cl. No. 7.3.1 IS 16046-1 |
| 11 | Information for safety | Cl. No. 8 IS 16046-1 |
| 12 | Insulation and wiring | Cl. No. 5.2 IS 16046-1 |
| 13 | Low pressure | Cl. No. 7.3.7 IS 16046-1 |
| 14 | Mechanical shock(Crash hazard) | Cl. No. 7.3.4 IS 16046-1 |
| 15 | Overcharge | Cl. No. 7.3.8 IS 16046-1 |
| 16 | Packaging | Cl. No. 10 IS 16046-1 |
| 17 | Parameter measurement Tolerance | IS 16046 (Part-1) Cl. 4 |
| 18 | Quality plan | IS 16046 (Part -1) Cl. 5.7 |
| 19 | Small Cell and Battery safety Information | IS 16046 (Part -1) Cl. 8.2 |
| 20 | Temperature cycling | Cl. No. 7.2.4 IS 16046-1 |
| 21 | Temperature, voltage and current management | Cl. No. 5.4 IS 16046-1 |
| 22 | Terminal contacts | Cl. No. 5.5 IS 16046-1 |
| 23 | Thermal Abuse(Cells) | Cl. No. 7.3.5 IS 16046-1 |
| 24 | Type test and Sample Size | IS 16046 (Part 1) Cl. 6 |
| 25 | Venting | Cl. No. 5.3 IS 16046-1 |
| 26 | Verification of Marking | Cl. No. 9 IS 16046-1 |
| 27 | Vibration | Cl. No. 7.2.2 IS 16046-1 |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes (Lithium)
| # | Test | Clause / method |
|---|---|---|
| 1 | Assembly of cells into batteries | Cl. No. 5.6 IS 16046-2 |
| 2 | Battery safety component | IS 16046 (Part -2) Cl. 5.8 |
| 3 | Case stress at high ambient temperature(Battery) | Cl. No. 7.2.2 IS 16046-2 |
| 4 | Charging procedure for test purpose | Cl. No.7.1 IS 16046-2 |
| 5 | Continuous charging at constant voltage (Cells) | Cl. No. 7.2.1 IS 16046-2 |
| 6 | Crush (cells) | Cl. No. 7.3.5 IS 16046-2 |
| 7 | External short circuit (cells) | Cl. No. 7.3.1 IS 16046-2 |
| 8 | External short circuit(Battery) | Cl. No. 7.3.2 IS 16046-2 |
| 9 | Forced Discharge(Cells) | Cl. No. 7.3.7 IS 16046-2 |
| 10 | Free Fall | Cl. No. 7.3.3 IS 16046-2 |
| 11 | General Safety Consideration | Cl. No. 5.1 IS 16046-2 |
| 12 | Information for safety | IS 16046 (Part -2) Cl. 8, 8.1, 8.2 |
| 13 | Insulation and wiring | Cl. No. 5.2 IS 16046-2 |
| 14 | Measurement of the internal AC resistance for coin cells (Annex. D) | IS 16046-2 Annex. D |
| 15 | Mechanical Shock (Battery) | Cl. 7.3.8.2 IS 16046 (Part -2) |
| 16 | Over-charging of battery | Cl. No. 7.3.6 IS 16046-2 |
| 17 | Packaging and transport | Cl. No. 10 IS 16046-2 |
| 18 | Parameter measurement Tolerance | IS 16046 (Part- 2) Cl.4 |
| 19 | Quality plan | IS 16046 (Part -2) Cl. 5.7 |
| 20 | Temperature, voltage and current management | Cl. No. 5.4 IS 16046-2 |
| 21 | Terminal contacts | Cl. No. 5.5 IS 16046-2 |
| 22 | Thermal Abuse(Cells) | Cl. No. 7.3.4 IS 16046-2 |
| 23 | Type test and sample size | IS 16046 (Part- 2) Cl.6 |
| 24 | Venting | Cl. No. 5.3 IS 16046-2 |
| 25 | Verification of Marking | Cl. No. 9 IS 16046-2 |
| 26 | Vibration | Cl. No. 7.3.8.1 IS 16046-2 |
How IS 16046 testing works
- Tell us the purpose. BIS certification, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to BIS, a tender authority or your customer, and help if they raise a query.
Need the ISI mark or CRS registration as well? See IS 16046 BIS certification for the products covered, the order, fees and process.
Frequently asked questions
Which IS 16046 tests are NABL accredited?
All 53 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IS 16046 shown next to it. The report carries the NABL accreditation mark for these tests.
Can the IS 16046 test report be used for BIS certification?
BIS accepts reports only from laboratories it has recognised for the standard. Before testing, we confirm which laboratory your BIS application needs, so you do not pay for a report BIS will not accept.
How many samples are needed for IS 16046 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IS 16046?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other battery & cell testing
- IS 16893 EV Lithium-ion Cells
- IS 14257 High Cranking Automotive Lead-Acid Batteries
- IS 16270 Solar PV Batteries
- IS 7372 Automotive Lead-Acid Batteries
- IS 16805 Industrial Lithium Batteries (Safety)
- IS 16822 Industrial Lithium Batteries (Performance)
- IS 1651 Stationary Tubular Lead-Acid Batteries
- IS 8320 Lead-Acid Storage Batteries
- IS 16047 Portable Lithium Cells (Performance)
- IS 1652 Stationary Planté Lead-Acid Batteries
- IS 13369 Tubular Monobloc Stationary Batteries
- IS 13514 Lead-Acid Batteries for Electric Road Vehicles
- IS 15549 Stationary VRLA Batteries
- IS 5154 Lead-Acid Traction Batteries
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- LED Lamp & Luminaire Testing 144 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 225 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.