Skip to content
NABL accredited testing

IEC 60896 Testing: Stationary Lead-Acid Batteries

NABL accredited testing of stationary lead-acid batteries to IEC 60896: 55 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardIEC 60896
CoversStationary lead-acid batteries –Valve regulated types; Stationary Cells and Batteries, Lead-Acid Type ( With Tubular Positive Plates); Stationary lead-acid batteries
Accredited tests55
AccreditationNABL, ISO/IEC 17025:2017
CategoryBattery & Cell Testing

IEC 60896 tests we offer

Stationary lead-acid batteries –Valve regulated types

#TestClause / method
1Impact of a stress temperature of 55°C to 60°CIEC 60896-21 Cl. no. 6.16
2recharge behaviorIEC 60896-21 Cl. no. 6.14
3short- circuit current and d.c. internal resistance informationIEC 60896-21 Cl. no. 6.3
4Abusive over- dischargesIEC 60896-21 Cl. no. 6.17
5Charge retention during storageIEC 60896-21 Cl. no. 6.12
6content and durability of required markingsIEC 60896-21 Cl. no. 6.6
7dimensional stability at elevated internal pressure and temperatureIEC 60896-21 Cl. no. 6.20
8Discharge capacityIEC 60896-21 Cl. no. 6.11
9Flammability rating of the materialsIEC 60896-21 Cl. no. 6.9
10Float service with daily dischargesIEC 60896-21 Cl. no. 6.13
11Gas emissionIEC 60896-21 Cl. no. 6.1
12High current toleranceIEC 60896-21 Cl. no. 6.2
13Low temperature service sensitivityIEC 60896-21 Cl. no. 6.19
14Protection against ground short propensityIEC 60896-21 Cl. no. 6.5
15Protection against internal ignition from external spark sourceIEC 60896-21 Cl. no. 6.4
16Reporting formatIEC 60896-22 Cl. No. 5
17Requirement for charge retention during storageIEC 60896-22 Cl. no. 6.12
18Requirement for content and durability of required markingsIEC 60896-22 Cl. no. 6.6
19Requirement for definition of the flammability rating of the materialsIEC 60896-22 Cl. no. 6.9
20Requirement for dimensional stability at elevated internal pressure and temperatureIEC 60896-22 Cl. no. 6.20
21Requirement for discharge capacity performanceIEC 60896-22 Cl. no. 6.11
22Requirement for float service with daily dischargesIEC 60896-22 Cl. no. 6.13
23Requirement for high current toleranceIEC 60896-22 Cl. no. 6.2
24Requirement for information on thermal runaway sensitivityIEC 60896-22 Cl. no. 6.18
25Requirement for protection against ground short propensityIEC 60896-22 Cl. no. 6.5
26Requirement for protection against internal ignition from external spark sourceIEC 60896-22 Cl. no. 6.4
27Requirement for recharge behaviorIEC 60896-22 Cl. no. 6.14
28Requirement for service life at an operating temperature of 40°CIEC 60896-22 Cl. no. 6.15
29Requirement for short- circuit current and d.c. internal resistance informationIEC 60896-22 Cl. no. 6.3
30Requirement for stability against mechanical absuse of units during installationIEC 60896-22 Cl. no. 6.21
31Requirement for the impact of a stress temperature of 55°C to 60°CIEC 60896-22 Cl. no. 6.16
32Requirement for the impact of abusive over- dischargesIEC 60896-22 Cl. no. 6.17
33Requirement for the impact of low temperature service on capacityIEC 60896-22 Cl. no. 6.19
34Requirement for the operation of the valveIEC 60896-22 Cl. no. 6.8
35Requirements for gas emission informationIEC 60896-22 Cl. no. 6.1
36Service life at an operating temperature of 40°CIEC 60896-21 Cl. no. 6.15
37Stability against mechanical abuses' of units during installationIEC 60896-21 Cl. no. 6.21
38Thermal runaway sensitivityIEC 60896-21 Cl. no. 6.18
39Valve operationIEC 60896-21 Cl. no. 6.8

Stationary Cells and Batteries, Lead-Acid Type ( With Tubular Positive Plates)

#TestClause / method
1Accuracy of measuring instrumentsIEC 60896-11 Cl. 12
2CapacityIEC 60896-11 Cl. 7
3Capacity testIEC 60896-11 Cl. 14
4Cell and battery markingsIEC 60896-11 Cl. 21
5Charge retentionIEC 60896-11 Cl. 10
6Charge retention testIEC 60896-11 Cl. 18
7Endurance in discharge- charge cyclesIEC 60896-11 Cl. 16
8Endurance in overchargeIEC 60896-11 Cl. 17
9Endurance TestIEC 60896-11 Cl. 9
10Preparation of cells and batteries for testingIEC 60896-11 Cl. 13
11Short-circuit current and internal resistanceIEC 60896-11 Cl. 11
12Short-circuit current and internal resistance determinationIEC 60896-11 Cl. 19
13Suitability for floating battery operationIEC 60896-11 Cl. 8
14Test of suitability for floating battery operationIEC 60896-11 Cl. 15
15Test sequenceIEC 60896-11 Cl. 20

Stationary lead-acid batteries

#TestClause / method
1Endurance TestIEC 60896-11 Cl. 9

How IEC 60896 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IEC 60896 tests are NABL accredited?

All 55 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IEC 60896 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the IEC 60896 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for IEC 60896 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IEC 60896?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other battery & cell testing

  • IS 16046 Portable Lithium & Nickel Cells and Batteries
  • IS 16893 EV Lithium-ion Cells
  • IS 14257 High Cranking Automotive Lead-Acid Batteries
  • IS 16270 Solar PV Batteries
  • IS 7372 Automotive Lead-Acid Batteries
  • IS 16805 Industrial Lithium Batteries (Safety)
  • IS 16822 Industrial Lithium Batteries (Performance)
  • IS 1651 Stationary Tubular Lead-Acid Batteries
  • IS 8320 Lead-Acid Storage Batteries
  • IS 16047 Portable Lithium Cells (Performance)
  • IS 1652 Stationary Planté Lead-Acid Batteries
  • IS 13369 Tubular Monobloc Stationary Batteries
  • IS 13514 Lead-Acid Batteries for Electric Road Vehicles
  • IS 15549 Stationary VRLA Batteries
  • IS 5154 Lead-Acid Traction Batteries
  • IEC 62133 Portable Lithium & Nickel Battery Safety
  • TEC 67030 Lithium-ion Batteries for Telecom
  • UL 1973 Stationary & Motive Batteries
  • IEC 62619 Industrial Lithium Battery Safety
  • IEC 62660 EV Lithium-ion Cells
  • UL 2054 Household & Commercial Batteries
  • AIS 038 EV Power Train Safety
  • IEC 62620 Industrial Lithium Battery Performance
  • IEC 61960 Portable Lithium Cells (Performance)
  • UL 1642 Lithium Cells
  • AIS 156 EV Power Train Safety (L Category)
  • JIS C 8702 Small VRLA Batteries
  • UN 38.3 Lithium Battery Transport
  • IEC 60254 Lead-Acid Traction Batteries
  • IEC 61427 Batteries for Renewable Energy Storage

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote