Skip to content
NABL accredited testing

BS EN 50182 Testing: Stranded Overhead Line Conductors

NABL accredited testing of stranded overhead line conductors to BS EN 50182: 8 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardBS EN 50182
CoversConductors For Overhead Lines Round Wire Concentric lay Stranded Conductors
Accredited tests8
AccreditationNABL, ISO/IEC 17025:2017
CategoryConductor & Insulating Mat Testing

BS EN 50182 tests we offer

#TestClause / method
1DimensionsBS EN 50182 Cl 6.4.2,, 6.5.2 and Table-5
2Lay Ratio And Direction Of LayBS EN 50182 Cl 5.5.2 to 5.5.7 & 6.4.4
3Nominal DC Resistance TestBS EN 50182 Cl 5.10
4Rated Tensile strength of ConductorCl. 5.0 of BS EN 50182
5ResistivityBS EN 50182 Cl 6.5.2
6Stress Strain CurvesBS EN 50182 6.4.7 & Annexure-C
7Surface ConditionBS EN 50182 Cl 5.3 & 6.4.1
8Tensile StrengthBS EN 50182 Cl 6.5.2 a

How BS EN 50182 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which BS EN 50182 tests are NABL accredited?

All 8 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS EN 50182 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the BS EN 50182 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for BS EN 50182 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of BS EN 50182?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other conductor & insulating mat testing

  • IS 398 Aluminium Conductors for Overhead Lines
  • IS 15652 Insulating Mats
  • BS 215 Aluminium & ACSR Overhead Conductors

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote