NABL accredited testing of fire resistant screened cables to BS 7629: 33 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardBS 7629
CoversElectric cables -Specification for 300/500V fire resistant screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire
Accredited tests33
AccreditationNABL, ISO/IEC 17025:2017
CategoryCable & Wire Testing

BS 7629 tests we offer

#TestClause / method
1Adherence TestCl. 8 & Table -5 of BS 7629-1
2Ageing in air oven of insulation and sheath Elongation testBS 7629-1
3Ageing in air oven of insulation and sheath Tensile strengthBS 7629-1
4Bending characteristicsCl. 16.4, Table -5 and Annex-D of BS 7629-1
5Cable markingCl. 11 & Table -5 of BS 7629-1
6Conductor and drain wire resistanceCl.14.2 & Table -5 of BS 7629-1 and BS EN 60228
7Core Identification :- Clarity and durabilityCl.7.2 & Table-5 of BS 7629-1
8Core Identification :- ColoursCl.7.1 & Table-5 of BS 7629-1
9Corrosive and acid gasCl.16.2, Table -5 of BS 7629-1 and BS EN 60754-1
10Durability of printed informationCl. 11.7 & Table -5 of BS 7629-1 and Cl.5.1 of BS EN 50396
11Flame propagation on single cableCl. 15.4 & Table -5 of BS 7629-1 and BS EN 60332-1-2
12Insulation :- ApplicationCl.6.2 & Table-5 of BS 7629-1
13Insulation :- MaterialCl.6.1 & Table-5 of BS 7629-1
14Insulation :- ThicknessCl.6.3 & Table-5 of BS 7629-1
15Laying -Up :- Direction and sequence of lay & Length of lay of assembledCl. 8 & Table -5 of BS 7629-1
16OvalityCl. 15.7, Table -5 of BS 7629-1 and Cl.4.4 of BS EN 50396
17Resistance to impactCl. 16.5, Table -5 and Annex-E of BS 7629-1
18Shrinkage of InsulationCl.16.3, Table -5 of BS 7629-1 and BS EN 60811-502
19Shrinkage test on sheathCl. 16.6, Table -5 and Annex-F of BS 7629-1
20Smoke emissionCl.15.5 & Table -5 of BS 7629-1 and BS EN 61032-2-2
21Test On Conductor :- ConstructionCl. 5.1, Table -5 of BS 7629-1 and BS EN 60228
22Test On Conductor :- Continuity of tinningCl.5.1, Table -5 & Annex B of BS 7629-1
23Test On Drain Wire :- ConstructionCl. 5.2, Table -5 of BS 7629-1 and BS EN 60228
24Test On Drain Wire :- Continuity of tinningCl.5.1, Table -5 & Annex B of BS 7629-1
25Test On Sheath :- MaterialCl.10.1 & Table -5 of BS 7629-1
26Test On Sheath :- ThicknessCl.10.3 & Table -5 of BS 7629-1 and Cl.4.2 of BS EN 50396
27Test to resistance to fire: Category ENHANCED 120Cl. 15.6.4, Table -5 and Annex- E of BS 7629-1 and BS EN 50200
28Test to resistance to fire: Category STANDARD 30Cl. 15.6.2, Table -5 and Annex- E of BS 7629-1 and BS EN 50200
29Test to resistance to fire: Category STANDARD 60Cl. 15.6.3, Table -5 and Annex- E of BS 7629-1 and BS EN 50200
30Voltage test on complete CableCl.14.3 & Table -5 of BS 7629-1 and Cl.10.3 of BS EN 50395
31Voltage WithstandCl. 15.2, Table -5 and Annex-C of BS 7629-1
32Screen: ApplicationCl.9 & Table -5 of BS 7629-1
33Test On Sheath :- ApplicationCl.10.2 & Table -5 of BS 7629-1

How BS 7629 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which BS 7629 tests are NABL accredited?

All 33 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS 7629 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the BS 7629 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for BS 7629 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of BS 7629?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other cable & wire testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.