IEC 60598 Testing: Luminaire Safety
NABL accredited testing of luminaire safety to IEC 60598: 119 tests, each against its clause.
Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.
| Standard | IEC 60598 |
|---|---|
| Covers | Lighting Chains; Rope Lights; Fixed General Purpose Luminaires; Flood Lights; Hand Lamps; Luminaires; Luminaires for Road and Street Lighting; Recessed Luminaires; Luminaires for Emergency Lighting |
| Accredited tests | 119 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| Category | LED Lamp & Luminaire Testing |
IEC 60598 tests we offer
Lighting Chains
| # | Test | Clause / method |
|---|---|---|
| 1 | Creepage Distances and Clearances | IEC 60598-2-20 (Clause 20.8) |
| 2 | Endurance Test and Thermal Test | IEC 60598-2-20 (Clause 20.13) |
| 3 | Classification of Luminaires | IEC 60598-2-20 (Clause 20.5) |
| 4 | Construction | IEC 60598-2-20 (Clause 20.7) |
| 5 | External and Internal Wiring | IEC 60598-2-20 (Clause 20.11) |
| 6 | Insulation Resistance and Electric Strength | IEC 60598-2-20 (Clause 20.15) |
| 7 | Marking | IEC 60598-2-20 (Clause 20.6) |
| 8 | Protection against Electric Shock | IEC 60598-2-20 (Clause 20.12) |
| 9 | Resistance to Dust and Moisture | IEC 60598-2-20 (Clause 20.14) |
| 10 | Resistance to Heat, Fire and Tracking | IEC 60598-2-20 (Clause 20.16) |
| 11 | Terminals | IEC 60598-2-20 (Clause 20.10) |
| 12 | Creepage Distance and Clearance | IEC 60598-2-20 Cl. 20.8 |
| 13 | Test for Interconnecting Connector for use in Lighting chain | IEC 60598-2-20 Annex A |
| 14 | General test requirements | IEC 60598-2-20 Cl. 20.4 |
| 15 | Resistance to Dust, Solid Objects and Moisture | IEC 60598-2-20 Cl. 20.14 |
Rope Lights
| # | Test | Clause / method |
|---|---|---|
| 1 | Construction | IEC 60598-2-21 |
| 2 | Endurance Test and Thermal Test | IEC 60598-2-21 |
| 3 | Insulation Resistance and Electric Strength | IEC 60598-2-21 |
| 4 | Marking | IEC 60598-2-21 |
| 5 | Terminals | IEC 60598-2-21 |
| 6 | Classification of Luminaires | IEC 60598-2-21 |
| 7 | Creepage Distances and Clearances | IEC 60598-2-21 |
| 8 | External and Internal Wiring | IEC 60598-2-21 |
| 9 | Protection against Electric Shock | IEC 60598-2-21 |
| 10 | Resistance to Dust and Moisture | IEC 60598-2-21 |
| 11 | Resistance to Heat, Fire and Tracking | IEC 60598-2-21 |
| 12 | Creepage Distance and Clearance | IEC 60598-2-21 Cl. 21.8 |
| 13 | General test requirements | IEC 60598-2-21 Cl. 21.4 |
| 14 | Resistance to Dust, Solid Objects and Moisture | IEC 60598-2-21 Cl. 21.14 |
| 15 | Test for Interconnecting Connector for use in Lighting chain | IEC 60598-2-21 Annex A |
Fixed General Purpose Luminaires
| # | Test | Clause / method |
|---|---|---|
| 1 | Endurance Test and Thermal Test | IEC 60598-2-1 (Clause 1.13) |
| 2 | Classification of Luminaires | IEC 60598-2-1 (Clause 1.4) |
| 3 | Construction | IEC 60598-2-1 (Clause 1.7) |
| 4 | Creepage Distance and Clearance | IEC 60598-2-1 (Clause 1.8) |
| 5 | External and Internal Wiring | IEC 60598-2-1 (Clause 1.11) |
| 6 | Insulation Resistance and Electric Strength | IEC 60598-2-1 (Clause 1.15) |
| 7 | Protection against Electric Shock | IEC 60598-2-1 (Clause 1.12) |
| 8 | Resistance to Heat, Fire and Tracking | IEC 60598-2-1 (Clause 1.16) |
| 9 | Terminals | IEC 60598-2-1 (Clause 1.10) |
| 10 | Marking | IEC 60598-2-1 (Clause 1.6) |
| 11 | Provision for Earthing | IEC 60598-2-1 (Clause 1.9) |
| 12 | Resistance to Dust and Moisture | IEC 60598-2-1 (Clause 1.14) |
| 13 | GENERAL TEST REQUIREMENTS | IEC 60598-2-1 Cl. 1.3 |
| 14 | Verification of Marking | IEC 60598-2-1 Cl. 1.5 |
Flood Lights
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaires | IEC 60598-2-5 (Clause 5.4) |
| 2 | Construction | IEC 60598-2-5 (Clause 5.6) |
| 3 | Creepage Distance and Clearance | IEC 60598-2-5 (Clause 5.7) |
| 4 | Endurance Test and Thermal Test | IEC 60598-2-5 (Clause 5.12) |
| 5 | External and Internal Wiring | IEC 60598-2-5 (Clause 5.10) |
| 6 | Flat Glass Cover Shattering | IEC 60598-2-5 (Clause 5.6.8) |
| 7 | Insulation Resistance and Electric Strength | IEC 60598-2-5 (Clause 5.14) |
| 8 | Marking | IEC 60598-2-5 (Clause 5.5) |
| 9 | Protection Against Electric Shock | IEC 60598-2-5 (Clause 5.11) |
| 10 | Provision for Earthing | IEC 60598-2-5 (Clause 5.8) |
| 11 | Resistance to Dust and Moisture | IEC 60598-2-5 (Clause 5.13) |
| 12 | Resistance to Heat, Fire and Tracking | IEC 60598-2-5 (Clause 5.15) |
| 13 | Terminals | IEC 60598-2-5 (Clause 5.9) |
| 14 | Wind Speed Test | IEC 60598-2-5 (Clause 5.6.5) |
Hand Lamps
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaires | IEC 60598-2-8 (Clause 8.5) |
| 2 | Construction | IEC 60598-2-8 (Clause 8.7) |
| 3 | Creepage Distance and Clearance | IEC 60598-2-8 (Clause 8.8) |
| 4 | Endurance Test and Thermal Test | IEC 60598-2-8 (Clause 8.13) |
| 5 | External and Internal Wiring | IEC 60598-2-8 (Clause 8.11) |
| 6 | Insulation Resistance and Electric Strength | IEC 60598-2-8 (Clause 8.15) |
| 7 | Marking | IEC 60598-2-8 (Clause 8.6) |
| 8 | Protection against Electric Shock | IEC 60598-2-8 (Clause 8.12) |
| 9 | Provision for Earthing | IEC 60598-2-8 (Clause 8.9) |
| 10 | Resistance to Dust and Moisture | IEC 60598-2-8 (Clause 8.14) |
| 11 | Resistance to Heat, Fire and Tracking | IEC 60598-2-8 (Clause 8.16) |
| 12 | Terminals | IEC 60598-2-8 (Clause 8.10) |
| 13 | General Test Requirements | IEC 60598-2-8 Cl. 8.4 |
Luminaires
| # | Test | Clause / method |
|---|---|---|
| 1 | Components of Luminaires | IEC 60598-1 (Section 0.5) |
| 2 | Construction | IEC 60598-1 (Section 4) |
| 3 | External and Internal Wiring | IEC 60598-1 (Section 5) |
| 4 | Marking | IEC 60598-1 (Section 3) |
| 5 | Resistance to Dust, Solid Objects and Moisture | IEC 60598-1 (Section 9) |
| 6 | Terminals | IEC 60598-1 (Section 14, 15) |
| 7 | Classification of Luminaires | IEC 60598-1 (Section 2) |
| 8 | Creepage Distance and Clearance | IEC 60598-1 (Section 11) |
| 9 | Endurance Test and Thermal Test | IEC 60598-1 (Section 12) |
| 10 | Insulation Resistance and Electric Strength | IEC 60598-1 (Section 10) |
| 11 | Protection against Electric Shock | IEC 60598-1 (Section 8) |
| 12 | Provision for Earthing | IEC 60598-1 (Section 7) |
| 13 | Resistance to Heat, Fire and Tracking | IEC 60598-1 (Section 13) |
Luminaires for Road and Street Lighting
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaires | IEC 60598-2-3 (Clause 3.4) |
| 2 | Construction | IEC 60598-2-3 (Clause 3.6) |
| 3 | Creepage Distances and Clearances | IEC 60598-2-3 (Clause 3.7) |
| 4 | Endurance Test and Thermal Test | IEC 60598-2-3 (Clause 3.12) |
| 5 | External and Internal Wiring | IEC 60598-2-3 (Clause 3.10) |
| 6 | Insulation Resistance and Electric Strength | IEC 60598-2-3 (Clause 3.14) |
| 7 | Marking | IEC 60598-2-3 (Clause 3.5) |
| 8 | Protection against Electric Shock | IEC 60598-2-3 (Clause 3.11) |
| 9 | Provision for Earthing | IEC 60598-2-3 (Clause 3.8) |
| 10 | Resistance to Dust and Moisture | IEC 60598-2-3 (Clause 3.13) |
| 11 | Resistance to Heat, Fire and Tracking | IEC 60598-2-3 (Clause 3.15) |
| 12 | Terminals | IEC 60598-2-3 (Clause 3.9) |
Recessed Luminaires
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaires | IEC 60598-2-2 (Clause 2.5) |
| 2 | Construction | IEC 60598-2-2 (Clause 2.7) |
| 3 | Creepage Distances and Clearances | IEC 60598-2-2 (Clause 2.8) |
| 4 | Endurance Test and Thermal Test | IEC 60598-2-2 (Clause 2.13) |
| 5 | External and Internal Wiring | IEC 60598-2-2 (Clause 2.11) |
| 6 | Insulation Resistance and Electric Strength | IEC 60598-2-2 (Clause 2.15) |
| 7 | Marking | IEC 60598-2-2 (Clause 2.6) |
| 8 | Protection against Electric Shock | IEC 60598-2-2 (Clause 2.12) |
| 9 | Provision for Earthing | IEC 60598-2-2 (Clause 2.9) |
| 10 | Resistance to Dust and Moisture | IEC 60598-2-2 (Clause 2.14) |
| 11 | Resistance to Heat, Fire and Tracking | IEC 60598-2-2 (Clause 2.16) |
| 12 | Terminals | IEC 60598-2-2 (Clause 2.10) |
Luminaires for Emergency Lighting
| # | Test | Clause / method |
|---|---|---|
| 1 | Classification of Luminaires | IEC 60598-2-22 (Clause 22.5) |
| 2 | Marking | IEC 60598-2-22 (Clause 22.6) |
| 3 | Provision for Earthing | IEC 60598-2-22 (Clause 22.9) |
| 4 | Creepage Distance and Clearance | IEC 60598-2-22 (Clause 22.8) |
| 5 | Endurance Test and Thermal Test | IEC 60598-2-22 (Clause 22.13) |
| 6 | External and Internal Wiring | IEC 60598-2-22 (Clause 22.11) |
| 7 | Insulation Resistance and Electric Strength | IEC 60598-2-22 (Clause 22.15) |
| 8 | Protection against Electric Shock | IEC 60598-2-22 (Clause 22.12) |
| 9 | Resistance to Dust and Moisture | IEC 60598-2-22 (Clause 22.14) |
| 10 | Resistance to Heat, Fire and Tracking | IEC 60598-2-22 (Clause 22.16) |
| 11 | Terminals | IEC 60598-2-22 (Clause 22.10) |
How IEC 60598 testing works
- Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.
Frequently asked questions
Which IEC 60598 tests are NABL accredited?
All 119 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IEC 60598 shown next to it. The report carries the NABL accreditation mark for these tests.
Is the IEC 60598 test report accepted outside India?
NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.
How many samples are needed for IEC 60598 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of IEC 60598?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other LED lamp & luminaire testing
- IS 10322 Luminaires
- IS 15885 LED Drivers (Control Gear)
- IS 16102 Self-Ballasted LED Lamps
- IS 16103 LED Modules for General Lighting
- IS 16107 LED Luminaire Performance
- IS 16104 LED Module Control Gear (Performance)
- IS 16106 LED Photometric & Electrical Measurements
- IEC 61347 Lamp Control Gear Safety
- IEC 62031 LED Module Safety
- IEC 62560 Self-Ballasted LED Lamps
- IEC 62612 Self-Ballasted LED Lamp Performance
- IEC 62722 Luminaire Performance
- IEC 62717 LED Module Performance
- IES LM 79 LED Photometric Measurements
- IEC 62384 LED Control Gear Performance
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- Overhead Line Hardware Testing 128 accredited tests
- LED Lamp & Luminaire Testing 573 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 312 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.