Skip to content
NABL accredited testing

BS EN 50397 Testing: Covered Conductor Accessories

NABL accredited testing of covered conductor accessories to BS EN 50397: 54 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardBS EN 50397
CoversAccessories for Covered Conductors; Covered Conductors For Overhead Lines And Related Accessorioes For Rated Voltages Above 1kV AC and not exceeding 36 kV AC -Covered Conductors
Accredited tests54
AccreditationNABL, ISO/IEC 17025:2017
CategoryOverhead Line Hardware Testing

BS EN 50397 tests we offer

Accessories for Covered Conductors

#TestClause / method
1Branch Cable Pull-out TestBS EN 50397-2 (Clause 7.5.14)
2Climatic Ageing TestBS EN 50397-2 (Clause 7.11.3)
3Corrosion TestsBS EN 50397-2 (Clause 7.12.2)
4Damage and Failure Load Test for Tension and Suspension ClampsBS EN 50397-2 (Clause 7.5.2)
5Environmental Tests for Connectors and JointsBS EN 50397-2 (Clause 7.12)
6Hot Dip Galvanizing TestBS EN 50397-2 (Clause 7.6)
7Lift Load and Side Load Test for Suspension Clamp at Ambient TemperatureBS EN 50397-2 (Clause 7.5.6)
8Low Temperature Assembly Test for JointsBS EN 50397-2 (Clause 7.5.17)
9Low Temperature Assembly TestBS EN 50397-2 (Clause 7.5.15)
10Shear Head Function TestBS EN 50397-2 (Clause 7.5.12)
11Slip Test at Ambient Temperature for Suspension ClampsBS EN 50397-2 (Clause 7.5.3)
12Slip Test at Low Temperature for Suspension ClampsBS EN 50397-2 (Clause 7.5.4)
13Slip Test for Suspension Clamps at High TemperatureBS EN 50397-2 (Clause 7.5.5)
14Tensile Test for Tension Clamps at High TemperatureBS EN 50397-2 (Clause 7.5.10)
15Test for Mechanical Damage to the Main ConductorBS EN 50397-2 (Clause 7.5.13)
16Test for Permanent MarkingBS EN 50397-2 (Clause 7.4)
17Thermal Test for Suspension ClampBS EN 50397-2 (Clause 7.5.7)
18Visual ExaminationBS EN 50397-2 (Clause 7.2)
19Water Tightness Test for IPCBS EN 50397-2 (Clause 7.7.1)
20Water Tightness Test for JointsBS EN 50397-2 (Clause 7.7.2)
21Tensile Test for Tension Clamps and Joints at Ambient TemperatureBS EN 50397-2 (Clause 7.5.8)
22Clamp Bolt Tightening TestBS EN 50397-2 (Clause 7.5.11)
23Corrosion Ageing TestBS EN 50397-2 (Clause 7.11.2)
24Dimensional and Material VerificationBS EN 50397-2 (Clause 7.3)
25Electrical Ageing Test for Connectors and JointsBS EN 50397-2 (Clause 7.8)
26Endurance Test for JointsBS EN 50397-2 (Clause 7.13)
27Environmental Test for Suspension and Tension ClampsBS EN 50397-2 (Clause 7.11)
28Tensile Test for Tension Clamps at Low TemperatureBS EN 50397-2 (Clause 7.5.9)

Covered Conductors For Overhead Lines And Related Accessorioes For Rated Voltages Above 1kV AC and not exceeding 36 kV AC -Covered Conductors

#TestClause / method
1Carbon Black ContentBS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.2, BS EN 60811-605, Cl 4.2
2Compliance With The design RequirementsBS EN 50397-1 Cl 4.2 & Cl 6 Table-2, S No-2.1
3Conductor ResistanceBS EN 50397-1, 2020 Cl 6 Table-2, SNo-1.1 & HD 605 S3: Cl 3.1.1
4Construction And Dimensions of The ConductorBS EN 50397-1 Cl 6 Table-2, SNo-3.2, 4.2.1
5Content,Legibility On MarkingBS EN 50397-1 Cl 5
6Durability On MarkingBS EN 50397-1 Cl 5.2
7Gravimetric Water AbsorptionBS EN 50397-1, 2020 Cl 6 Table-2, SNo-7.1,BS EN 60811-402, Cl 4.2
8Hot Set TestBS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.2,BS EN 60811-507 Cl 4.3
9Mechanical Properties (Elongation) Before AgeingBS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1a & BS EN 60811-501 Cl 4.2
10Mechanical Properties, Tensile Strength After AgeingBS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1 b &BS EN 60811-401 Cl 4.2.3.2
11Mechanical Propertiies (Tensile Strength) Before AgeingBS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1a & BS EN 60811-501
12Pressure TestBS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.3,BS EN 60811-508 Cl 4.3
13Rated Tensile Strength On ConductorBS EN 50397-1 Cl 6 Table-2, SNo-3.1, 4.2.1
14Resistance to UV Ray (Tensile Strength)BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.3 ASTM G 154 Cl 9
15Resistance To UV Rays (Elongation)BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.3ASTM G 154 Cl 9
16Shrinkage TestBS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.1 & BS EN 60811-502 Cl 4.2
17Test For Compatibility (Elongation)BS EN 50397-1, 2020 Cl 6 Table-2, SNo-5,BS EN 60811-401, Cl 4.2.3.4
18Test For Compatibility (Tensile Strength)BS EN 50397-1, 2020 Cl 6 Table-2, SNo-5 & BS EN 60811-401, Cl 4.2.3.4
19Thickness On CoveringBS EN 50397-1, 2020 Cl 6 Table-2, SNo-2.2,BS EN 60811-201 Cl 4.2
20High voltage testBS EN 50397-1, 2020
21Leakage current testBS EN 50397-1:2020, Annex A
22Mechanical Properties (Elongation) After AgeingBS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1 bBS EN 60811-401 Cl 4.2.3.2
23Shore D hardness testBS EN 50397-1:2020, HD 605 S3:2019
24Slippage testBS EN 50397-1:2020, Annex A
25Test of the Longitudinal Water tightnessBS EN 50397-1:2020, IEC 60502-2:2014
26Tracking Resistance testBS EN 50397-1:2020, Annex B

How BS EN 50397 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which BS EN 50397 tests are NABL accredited?

All 54 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS EN 50397 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the BS EN 50397 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for BS EN 50397 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of BS EN 50397?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other overhead line hardware testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote