BS EN 50397 Testing: Covered Conductor Accessories
NABL accredited testing of covered conductor accessories to BS EN 50397: 54 tests, each against its clause.
Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.
| Standard | BS EN 50397 |
|---|---|
| Covers | Accessories for Covered Conductors; Covered Conductors For Overhead Lines And Related Accessorioes For Rated Voltages Above 1kV AC and not exceeding 36 kV AC -Covered Conductors |
| Accredited tests | 54 |
| Accreditation | NABL, ISO/IEC 17025:2017 |
| Category | Overhead Line Hardware Testing |
BS EN 50397 tests we offer
Accessories for Covered Conductors
| # | Test | Clause / method |
|---|---|---|
| 1 | Branch Cable Pull-out Test | BS EN 50397-2 (Clause 7.5.14) |
| 2 | Climatic Ageing Test | BS EN 50397-2 (Clause 7.11.3) |
| 3 | Corrosion Tests | BS EN 50397-2 (Clause 7.12.2) |
| 4 | Damage and Failure Load Test for Tension and Suspension Clamps | BS EN 50397-2 (Clause 7.5.2) |
| 5 | Environmental Tests for Connectors and Joints | BS EN 50397-2 (Clause 7.12) |
| 6 | Hot Dip Galvanizing Test | BS EN 50397-2 (Clause 7.6) |
| 7 | Lift Load and Side Load Test for Suspension Clamp at Ambient Temperature | BS EN 50397-2 (Clause 7.5.6) |
| 8 | Low Temperature Assembly Test for Joints | BS EN 50397-2 (Clause 7.5.17) |
| 9 | Low Temperature Assembly Test | BS EN 50397-2 (Clause 7.5.15) |
| 10 | Shear Head Function Test | BS EN 50397-2 (Clause 7.5.12) |
| 11 | Slip Test at Ambient Temperature for Suspension Clamps | BS EN 50397-2 (Clause 7.5.3) |
| 12 | Slip Test at Low Temperature for Suspension Clamps | BS EN 50397-2 (Clause 7.5.4) |
| 13 | Slip Test for Suspension Clamps at High Temperature | BS EN 50397-2 (Clause 7.5.5) |
| 14 | Tensile Test for Tension Clamps at High Temperature | BS EN 50397-2 (Clause 7.5.10) |
| 15 | Test for Mechanical Damage to the Main Conductor | BS EN 50397-2 (Clause 7.5.13) |
| 16 | Test for Permanent Marking | BS EN 50397-2 (Clause 7.4) |
| 17 | Thermal Test for Suspension Clamp | BS EN 50397-2 (Clause 7.5.7) |
| 18 | Visual Examination | BS EN 50397-2 (Clause 7.2) |
| 19 | Water Tightness Test for IPC | BS EN 50397-2 (Clause 7.7.1) |
| 20 | Water Tightness Test for Joints | BS EN 50397-2 (Clause 7.7.2) |
| 21 | Tensile Test for Tension Clamps and Joints at Ambient Temperature | BS EN 50397-2 (Clause 7.5.8) |
| 22 | Clamp Bolt Tightening Test | BS EN 50397-2 (Clause 7.5.11) |
| 23 | Corrosion Ageing Test | BS EN 50397-2 (Clause 7.11.2) |
| 24 | Dimensional and Material Verification | BS EN 50397-2 (Clause 7.3) |
| 25 | Electrical Ageing Test for Connectors and Joints | BS EN 50397-2 (Clause 7.8) |
| 26 | Endurance Test for Joints | BS EN 50397-2 (Clause 7.13) |
| 27 | Environmental Test for Suspension and Tension Clamps | BS EN 50397-2 (Clause 7.11) |
| 28 | Tensile Test for Tension Clamps at Low Temperature | BS EN 50397-2 (Clause 7.5.9) |
Covered Conductors For Overhead Lines And Related Accessorioes For Rated Voltages Above 1kV AC and not exceeding 36 kV AC -Covered Conductors
| # | Test | Clause / method |
|---|---|---|
| 1 | Carbon Black Content | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.2, BS EN 60811-605, Cl 4.2 |
| 2 | Compliance With The design Requirements | BS EN 50397-1 Cl 4.2 & Cl 6 Table-2, S No-2.1 |
| 3 | Conductor Resistance | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-1.1 & HD 605 S3: Cl 3.1.1 |
| 4 | Construction And Dimensions of The Conductor | BS EN 50397-1 Cl 6 Table-2, SNo-3.2, 4.2.1 |
| 5 | Content,Legibility On Marking | BS EN 50397-1 Cl 5 |
| 6 | Durability On Marking | BS EN 50397-1 Cl 5.2 |
| 7 | Gravimetric Water Absorption | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-7.1,BS EN 60811-402, Cl 4.2 |
| 8 | Hot Set Test | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.2,BS EN 60811-507 Cl 4.3 |
| 9 | Mechanical Properties (Elongation) Before Ageing | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1a & BS EN 60811-501 Cl 4.2 |
| 10 | Mechanical Properties, Tensile Strength After Ageing | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1 b &BS EN 60811-401 Cl 4.2.3.2 |
| 11 | Mechanical Propertiies (Tensile Strength) Before Ageing | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1a & BS EN 60811-501 |
| 12 | Pressure Test | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.3,BS EN 60811-508 Cl 4.3 |
| 13 | Rated Tensile Strength On Conductor | BS EN 50397-1 Cl 6 Table-2, SNo-3.1, 4.2.1 |
| 14 | Resistance to UV Ray (Tensile Strength) | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.3 ASTM G 154 Cl 9 |
| 15 | Resistance To UV Rays (Elongation) | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.3ASTM G 154 Cl 9 |
| 16 | Shrinkage Test | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-6.1 & BS EN 60811-502 Cl 4.2 |
| 17 | Test For Compatibility (Elongation) | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-5,BS EN 60811-401, Cl 4.2.3.4 |
| 18 | Test For Compatibility (Tensile Strength) | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-5 & BS EN 60811-401, Cl 4.2.3.4 |
| 19 | Thickness On Covering | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-2.2,BS EN 60811-201 Cl 4.2 |
| 20 | High voltage test | BS EN 50397-1, 2020 |
| 21 | Leakage current test | BS EN 50397-1:2020, Annex A |
| 22 | Mechanical Properties (Elongation) After Ageing | BS EN 50397-1, 2020 Cl 6 Table-2, SNo-4.1 bBS EN 60811-401 Cl 4.2.3.2 |
| 23 | Shore D hardness test | BS EN 50397-1:2020, HD 605 S3:2019 |
| 24 | Slippage test | BS EN 50397-1:2020, Annex A |
| 25 | Test of the Longitudinal Water tightness | BS EN 50397-1:2020, IEC 60502-2:2014 |
| 26 | Tracking Resistance test | BS EN 50397-1:2020, Annex B |
How BS EN 50397 testing works
- Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
- Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
- Send samples. We help with labels, the test request and any technical documents the tests need.
- Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
- Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.
Frequently asked questions
Which BS EN 50397 tests are NABL accredited?
All 54 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of BS EN 50397 shown next to it. The report carries the NABL accreditation mark for these tests.
Is the BS EN 50397 test report accepted outside India?
NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.
How many samples are needed for BS EN 50397 testing?
It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.
Can you test only some clauses of BS EN 50397?
Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.
Other overhead line hardware testing
- IS 2121 Conductor & Earthwire Accessories for Overhead Lines
- IS 2486 Insulator Fittings for Overhead Lines
- BS EN 50483 Aerial Bundled Cable Accessories
- NF C 33-021 Pre-Insulated Joint Sleeves & Lugs
- NF C 33-020 Insulation Piercing Connectors
- NF C 33-041 Anchoring Clamps
- NF C 33-040 Suspension Clamps
All NABL testing categories
- Cable & Wire Testing 1,558 accredited tests
- Conductor & Insulating Mat Testing 134 accredited tests
- Battery & Cell Testing 583 accredited tests
- Household Appliance Testing 384 accredited tests
- Overhead Line Hardware Testing 128 accredited tests
- LED Lamp & Luminaire Testing 573 accredited tests
- IT & Electronics Safety Testing 181 accredited tests
- UPS Safety Testing 46 accredited tests
- Environmental & Reliability Testing 312 accredited tests
See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).
Not sure which certification your product needs?
Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.