Skip to content
NABL accredited testing

IEC 60068 Testing: Environmental Testing

NABL accredited testing of environmental testing to IEC 60068: 36 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardIEC 60068
CoversElectrical, Electronic and Mechanical Items; Electrical, electronic and other items; Enclosures for Electrical Equipment against External Mechanical Impacts; 48F Metal Free Optical Fiber Cable with Double HDPE Sheath for Underground Duct Application (Type-I) (Optical Fiber Cable); Degree of Protection Provided by Enclosures for Electrical equipment against external Mechanical impacts
Accredited tests36
AccreditationNABL, ISO/IEC 17025:2017
CategoryEnvironmental & Reliability Testing

IEC 60068 tests we offer

Electrical, Electronic and Mechanical Items

#TestClause / method
1Rough Handling Shock (Drop Test)IEC 60068-2-31
2Change in Temperature TestIEC 60068-2-14
3Cold TestIEC 60068-2-1
4Composite Temperature/Humidity Cyclic TestIEC 60068-2-38
5Damp Heat Test (Cyclic)IEC 60068-2-30
6Damp Heat Test (Steady State)IEC 60068-2-78
7Dry Heat TestIEC 60068-2-2
8Salt MistIEC 60068-2-11
9Salt Spray TestIEC 60068-2-52
10Shock TestIEC 60068-2-27
11Vibration (Sinusoidal)IEC 60068-2-6
12Vibration Test (Random)IEC 60068-2-64
13Drop and toppleIEC60068-2-31(cl.no. 5.1)
14Dust and sandIEC 60068-2-68
15Free fall testIEC60068-2-31(Cl.no.5.2)
16Damp Heat TestIEC60068(Part2/Sec78)
17Damp Heat, Steady StateIEC60068(Part2/Sec67)
18Low air pressureIEC60068-2-13

Electrical, electronic and other items

#TestClause / method
1Change in Temperature TestIEC 60068-2-14
2Cold TestIEC 60068-2-1
3Composite temperature/humidity cyclic testIEC 60068-2-38
4Damp Heat Test (Cyclic)IEC 60068-2-30
5Damp Heat Test (Steady State)IEC 60068-2-78
6Dry Heat TestIEC 60068-2-2
7Flowing mixed gas corrosion testIEC 60068-2-60
8Rough Handling shock (Drop Test)IEC 60068-2-31
9Salt MistIEC 60068-2-11
10Salt Spray TestIEC 60068-2-52
11Sealing TestIEC 60068-2-17
12Shock TestIEC 60068-2-27
13Vibration (Sinusoidal)IEC 60068-2-6
14Vibration Test (Random)IEC 60068-2-64

Enclosures for Electrical Equipment against External Mechanical Impacts

#TestClause / method
1Pendulum Hammer TestIEC 60068-2-75 (Clause 5)
2Spring Hammer TestIEC 60068-2-75 (Clause 6)

48F Metal Free Optical Fiber Cable with Double HDPE Sheath for Underground Duct Application (Type-I) (Optical Fiber Cable)

#TestClause / method
1UV Radiation Test (2000 Hrs.)IEC 60068-2-1 / ASTM G-154-12a/ ASTM G-53-96 & TEC 85240

Degree of Protection Provided by Enclosures for Electrical equipment against external Mechanical impacts

#TestClause / method
1Test for IK Code 01 to IK Code 10IEC 60068-2-75 Cl.6.0

How IEC 60068 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IEC 60068 tests are NABL accredited?

All 36 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IEC 60068 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the IEC 60068 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for IEC 60068 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IEC 60068?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other environmental & reliability testing

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote