Skip to content
NABL accredited testing

IEC 60335 Testing: Household Appliance Safety

NABL accredited testing of household appliance safety to IEC 60335: 150 tests, each against its clause.

Independent private consultancy. Aaditech is not BIS or any government department and is not affiliated with or endorsed by them. Licences are granted only by the authority, and you can apply directly on its portal. Our consultancy fees are separate from official fees.

StandardIEC 60335
CoversAppliances for Heating Liquids; Electric immersion water heater; Stationary Storage Type Electric Water Heater; Cooking Ranges, Hobs, Ovens & Similar Appliances; Electric Instantaneous Water Heaters; Battery Charger; Cooking Ranges, Hobs, Ovens and Similar Appliances
Accredited tests150
AccreditationNABL, ISO/IEC 17025:2017
CategoryHousehold Appliance Testing

IEC 60335 tests we offer

Appliances for Heating Liquids

#TestClause / method
1Abnormal OperationIEC 60335-2-15: Cl.19
2ComponentsIEC 60335-2-15: Cl. 24
3ConstructionIEC 60335-2-15: Cl. 22
4Internal WiringIEC 60335-2-15: Cl. 23
5Mechanical StrengthIEC 60335-2-15: Cl. 21
6Provision for EarthingIEC 60335-2-15: Cl. 27
7Screws And ConnectionsIEC 60335-2-15 :Cl. 28
8Stability And Mechanical HazardsIEC 60335-2-15 Cl. 20
9Supply Connections and External Flexible CordsIEC 60335-2-15: Cl. 25
10Terminals for External ConductorsIEC 60335-2-15: Cl. 26
11Clearances, Creepage Distances and Solid InsulationIEC 60335-2-15: Cl :29
12HeatingIEC 60335-2-15: Cl. 11
13Leakage Current And Electric StrengthIEC 60335-2-15: Cl. :16
14Leakage Current At Operating Temperature / Leakage Current And Electric Strength At Operating TemperatureIEC 60335-2-15
15Marking / Marking & InstructionsIEC 60335-2-15: Cl. 7
16Moisture ResistanceIEC 60335-2-15: Cl. 15
17Overload Protection Of Transformers And Associated Circuits/Overload ProtectionIEC 60335-2-15 (Cl. 17)
18Power Input and CurrentIEC 60335-2-15: Cl. 10
19Protection against electric shock/ Protection against access to live PartsIEC 60335-2-15: Cl. 8
20Resistance To Heat, Fire and TrackingIEC 60335-2-15: Cl. 30
21Resistance To RustingIEC 60335-2-15: Cl. 31
22Starting of Motor- Operated AppliancesIEC 60335-2-15: Cl. 9
23Transient Over Voltage TestIEC 60335-2-15: Cl. 14
24ClassificationIEC 60335-2-15: Cl. 6
25GENERAL CONDITIONS FOR THE TESTSIEC 60335-2-15: Cl. 6
26GENERAL REQUIREMENTSIEC 60335-2-15: Cl. 4

Electric immersion water heater

#TestClause / method
1Abnormal OperationIEC 60335-2-74:Cl 19
2ComponentsIEC 60335-2-74:Cl. 24
3ConstructionIEC 60335-2-74:Cl 22
4Internal WiringIEC 60335-2-74:Cl. 23
5Mechanical StrengthIEC 60335-2-74 Cl. 21
6Provision for EarthingIEC 60335-2-74:Cl 27
7Screws And ConnectionsIEC 60335-2-74:Cl 28
8Stability And Mechanical HazardsIEC 60335-2-74:Cl 20
9Supply Connections and External Flexible CordsIEC 60335-2-74:Cl 25
10Terminals for External ConductorsiEC 60335-2-74:Cl. 26
11(After Humidity Treatment)/Leakage Current And Electric StrengthIEC 60335-2-74:Cl 16
12ClassificationIEC 60335-2-74:Cl. 6
13Clearances, Creepage Distances and Solid InsulationIEC 60335-2-74:Cl. 29
14EnduranceIEC 60335-2-74:Cl. 18
15GENERAL CONDITION FOR THE TESTSIEC 60335-2-74:Cl. 6
16GENERAL REQUIREMENTIEC 60335-2-74:Cl. 4
17HeatingIEC 60335-2-74:Cl. 11
18Leakage Current And Electric Strength At Operating TemperatureIEC 60335-2-74:Cl 13
19Marking & InstructionsIEC 60335-2-74:Cl. 7
20Moisture ResistanceIEC 60335-2-74:Cl 15
21Overload Protection Of Transformers And Associated Circuits/Overload ProtectionIEC 60335-2-74:Cl. 17
22Power Input and CurrentIEC 60335-2-74:Cl. 10
23Protection against electric shock/ Protection against access to live PartsIEC 60335-2-74:Cl 8
24Resistance To Heat, Fire and TrackingIEC 60335-2-74 Cl. 30
25Resistance To RustingIEC 60335-2-74 Cl. 31
26Transient Over Voltage TestIEC 60335-2-74 Cl. 14

Stationary Storage Type Electric Water Heater

#TestClause / method
1(After Humidity Treatment)/Leakage Current And Electric StrengthIEC 60335-2-21 Cl. 16
2Abnormal OperationIEC 60335-2-21 Cl. 19
3ClassificationIEC 60335-2-21 Cl. 6
4Clearance and creepage DistancesIEC 60335-2-21 Cl. 29
5ComponentsIEC 60335-2-21 Cl. 24
6ConstructionIEC 60335-2-21 Cl. 22
7Electrical Insulation And Leakage Current At Operating Temperature / Leakage Current And Electric Strength At Operating TemperatureIEC 60335-2-21 Cl. 13
8Input And Current /Power Input and CurrentIEC 60335-2-21 Cl. 20
9Internal WiringIEC 60335-2-21 Cl. 23
10Marking / Marking & InstructionsIEC 60335-2-21 Cl. 7
11Mechanical StrengthIEC 60335-2-21 Cl. 21
12Moisture ResistanceIEC 60335-2-21: Cl.15
13Overload Protection Of Transformers And Associated Circuits/Overload ProtectionIEC 60335-2-21 Cl. 17
14Protection Against Electric Shock / Protection Against Access To Live PartsIEC 60335-2-21 Cl. 8
15Provision For EarthingIEC 60335-2-21 Cl. 27
16Resistance to heat and FireIEC 60335-2-21 Cl. 30
17Resistance to RustingIEC 60335-2-21 Cl. 31
18Screws And ConnectionsIEC 60335-2-21 Cl. 28
19Stability And Mechanical HazardsIEC 60335-2-21 Cl. 20
20Supply Connection & External Flexible Cables & Cords / Supply Connection & External Flexible CordsIEC 60335-2-21 Cl. 25
21Temperature Rise /HeatingIEC 60335-2-21: Cl.11
22Terminals For External ConductorsIEC 60335-2-21 Cl. 26
23Transient Over Voltage TestIEC 60335-2-21 Cl. 14
24General Conditions for the TestsIEC 60335-2-21 Cl. 5
25General RequirementsIEC 60335-2-21 Cl. 4

Cooking Ranges, Hobs, Ovens & Similar Appliances

#TestClause / method
1ComponentsIEC 60335-2-6: Cl. 24
2Internal WiringIEC 60335-2-6: Cl. 23
3Resistance To Heat, Fire and TrackingIEC 60335-2-6, Cl. 30
4Resistance To RustingIEC 60335-2-6: Cl.31
5Abnormal OperationIEC 60335-2-6:Cl.19
6ClassificationIEC 60335-2-6: Cl. 6
7Clearances, Creepage Distances and Solid InsulationIEC 60335-2-6: Cl. 29
8ConstructionIEC 60335-2-6: Cl. 22
9HeatingIEC 60335-2-6:Cl.11
10Leakage Current And Electric StrengthIEC 60335-2-6: Cl. 16
11Leakage Current And Electric Strength At Operating TemperatureIEC 60335-2-6: Cl.13
12Marking& InstructionsIEC 60335-2-6:Cl.7
13Moisture ResistanceIEC 60335-2-6: Cl. 15
14Overload Protection Of Transformers And Associated Circuits/Overload ProtectionIEC 60335-2-6: Cl. 17
15Protection against electric shock/ Protection against access to live PartsIEC 60335-2-6: Cl. 10
16Provision for EarthingIEC 60335-2-6: Cl. 27
17Screws And ConnectionsIEC 60335-2-6: Cl. 28
18Stability And Mechanical HazardsIEC 60335-2-6:Cl:20
19Starting of Motor- Operated AppliancesIEC 60335-2-6: Cl. 9
20Supply Connections and External Flexible CordsIEC 60335-2-6:Cl 25
21Terminals for External ConductorsIEC 60335-2-6: Cl. 26
22Transient Over Voltage TestIEC 60335-2-6: Cl. 14
23Mechanical StrengthIEC 60335-2-6
24Power Input and CurrentIEC 60335-2-6: Cl.10

Electric Instantaneous Water Heaters

#TestClause / method
1(After Humidity Treatment)/Leakage Current And Electric StrengthIEC 60335-2-35 Cl. 16
2Abnormal OperationIEC 60335-2-35 Cl. 19
3ClassificationIEC 60335-2-35 Cl. 6
4Clearance and creepage DistancesIEC 60335-2-35:Cl.29
5ComponentsIEC 60335-2-35:Cl. 24
6ConstructionIEC 60335-2-35 Cl. 22
7Electrical Insulation And Leakage Current At Operating Temperature / Leakage Current And Electric Strength At Operating TemperatureIEC 60335-2-35 Cl. 13
8General RequirementsIEC 60335-2-35
9Input And Current /Power Input and CurrentIEC 60335-2-35 Cl. 10
10Internal WiringIEC 60335-2-35 Cl.23
11Marking / Marking & InstructionsIEC 60335-2-35 Cl. 17
12Mechanical StrengthIEC 60335-2-35 Cl. 21
13Moisture ResistanceIEC 60335-2-35 Cl. 15
14Overload Protection Of Transformers And Associated Circuits/Overload ProtectionIEC 60335-2-35 Cl. 17
15Protection Against Electric Shock / Protection Against Access To Live PartsIEC 60335-2-35 Cl. 8
16Provision For EarthingIEC 60335-2-35 Cl. 27
17Resistance to heat and FireIEC 60335-2-35 Cl. 30
18Resistance to RustingIEC 60335-2-35 Cl. 31
19Screws And ConnectionsIEC 60335-2-35 Cl. 28
20Stability And Mechanical HazardsIEC 60335-2-35 Cl. 20
21Supply Connection & External Flexible Cables & Cords / Supply Connection & External Flexible CordsIEC 60335-2-35:Cl.25
22Temperature Rise /HeatingIEC 60335-2-35 Cl. 11
23Terminals For External ConductorsIEC 60335-2-21:Cl. 26
24Transient Over Voltage TestIEC 60335-2-35 Cl. 14

Battery Charger

#TestClause / method
1ConstructionIEC 60335-2-29: Cl.22
2Abnormal operationsIEC 60335-2-29; Cl. 19
3ClassificationIEC 60335-2-29: Cl. 6
4Clearances, Creepage distances and solid insulationIEC 60335-2-29: Cl. 29
5HeatingIEC 60335-2-29 Cl. 11
6Internal WiringIEC 60335-2-29: Cl.23
7Leakage current and electric strengthIEC 60335-2-29: Cl. 16
8Leakage current and electric strength at operating temperatureIEC 60335-2-29: Cl. 13
9Mechanical StrengthIEC 60335-2-29: Cl. 21
10Moisture resistanceIEC 60335-2-29: Cl. 15
11Overload protection of transformers and associated circuitsIEC 60335-2-29: Cl. 17
12Power input and currentIEC 60335-2-29 Cl. 10
13Protection against access to live partsIEC 60335-2-29: Cl. 8
14Provision for EarthingIEC 60335-2-29: Cl. 27
15Resistance to heat and fireIEC 60335-2-29: Cl. 30
16Resistance to rustingIEC 60335-2-29: Cl. 31
17Screws and connectionsIEC 60335-2-29: Cl. 28
18Stability and mechanical hazardsIEC 60335-2-29: Cl. 20
19Supply connection and external flexible cordsIEC 60335-2-29: Cl. 25
20Terminals for external conductorsIEC 60335-2-29 Cl. 26
21Transient overvoltagesIEC 60335-2-29: Cl. 14
22Verification of ComponentsIEC 60335-2-29: Cl. 24
23Verification of Marking & InstructionsIEC 60335-2-29; Cl. 7

Cooking Ranges, Hobs, Ovens and Similar Appliances

#TestClause / method
1General conditions for the testsIEC 60335-2-6: Cl. 5
2General RequirementIEC 60335-2-6: Cl. 4

How IEC 60335 testing works

  1. Tell us the purpose. Export, a tender, a customer requirement or a design check. The purpose decides which clauses and which laboratory.
  2. Get the sample list and quote. We confirm the tests, the number of samples and the timeline for your product and its variants.
  3. Send samples. We help with labels, the test request and any technical documents the tests need.
  4. Testing and report. Tests are carried out under NABL accreditation and the report lists each clause, the requirement and the result.
  5. Review and use. We check the report before you submit it to a regulator, a tender authority or your customer, and help if they raise a query.

Frequently asked questions

Which IEC 60335 tests are NABL accredited?

All 150 tests listed on this page are within NABL accreditation (ISO/IEC 17025), each against the clause of IEC 60335 shown next to it. The report carries the NABL accreditation mark for these tests.

Is the IEC 60335 test report accepted outside India?

NABL is a signatory to the ILAC Mutual Recognition Arrangement, so its accredited reports are recognised by accreditation bodies in other member countries. Your buyer or regulator still decides what it accepts, so we confirm their requirement before testing.

How many samples are needed for IEC 60335 testing?

It depends on the product, its variants and the tests you need. Share the product details and the purpose of the test (BIS, tender or customer) and we will send the sample list and a quote.

Can you test only some clauses of IEC 60335?

Yes. For a tender, a customer complaint or a design check, we can test selected clauses. For BIS certification or a type test, every applicable clause has to be covered.

Other household appliance testing

  • IS 302 Household Electrical Appliance Safety
  • IS 368 Immersion Water Heaters
  • IS 2082 Storage Water Heaters (Geysers)

All NABL testing categories

See the NABL testing service for how we work. Tests listed are within NABL accreditation (ISO/IEC 17025).

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.