Skip to content
Indian Standard · ISI & CRS

IS 302 BIS Certification

20 products must be certified by BIS against IS 302, under both the ISI mark (Scheme-I) and CRS registration (Scheme-II). Find your product and its exact part below.

Products under IS 302

ProductPart / editionScheme
Electric Iron IS 302 (Part 2/Sec 3) ISI mark
Electric Immersion Water-heaters IS 302 (Part 2/Sec 201) ISI mark
Electric Stoves IS 302 (Part 2/Sec 202) ISI mark
Room Heaters IS 302 (Part 2/Sec 30) ISI mark
Hand-held Blender IS 302 (Part 2/ Section 14) ISI mark
Toasters, Grills, Roasters and Similar Appliances IS 302 (Part 2/Sec 9): 2009 ISI mark
Range Hoods IS 302 (Part 2/Sec 31): 2009 ISI mark
Appliances for Skin or Hair Care IS 302 (Part 2/Sec 23): 2009 ISI mark
Fans IS 302 (Part 2/ Sec 80): 2017 ISI mark
Commercial Dispensing Appliances and Vending Machines IS 302 (Part 2/Sec 75): 2018 ISI mark
Domestic Electric Clothes Washing Machines IS 302 (Part 2/Sec 7): 2010 ISI mark
Appliances for Stationary Storage Type Electric Water Heaters IS 302 (Part 2/Sec 21): 2018 ISI mark
Appliances for Electric Instantaneous Water Heaters IS 302 (Part 2/Sec 35): 2017 ISI mark
All Electrical Appliances Vacuum Cleaners and Water Suction Cleaning Appliances IS 302 (Part 1) : 2024 IEC 60335-1:2020 ISI mark
Electric Fence Energizers IS 302-2-76:1999 ISI mark
Microwave Ovens IS 302-2-25
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens
CRS
Mains-Powered Electronic Clocks IS 302-2:26
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 26 Clocks
CRS
Adapters for Household Appliances IS 302 (Part 1): 2008
Safety of Household and similar electrical appliances Part 1 General requirements
CRS
Induction Stove IS 302 (Part 2): Section 6: 2009
Safety of household and similar electrical appliances: part 2 particular requirements, section 6 cooking ranges, hobs, ovens and similar appliances
CRS
Rice Cooker IS 302 (Part 2): Section 15: 2009
safety of household and similar electrical appliances: part 2 particular requirements: section 15 appliances for heating liquids
CRS

Parts of IS 302 at a glance

PartCurrent editionAmendmentsOperative ISI licencesMin. marking fee (large unit)
IS 302 (Part 2/Sec 3)
Electric Iron
IS 302 (Part 2/Sec 3):2024 1 160 ₹73,000
IS 302 (Part 2/Sec 201)
Electric Immersion Water-heaters
IS 302 (Part 2/Sec 201):2008 1 60 ₹66,000
IS 302 (Part 2/Sec 202)
Electric Stoves
IS 302 (Part 2/Sec 202):1992 2 1 ₹75,000
IS 302 (Part 2/Sec 30)
Room Heaters
IS 302 (Part 2/Sec 30):2007 3 115 ₹85,000
IS 302 (Part 2/ Section 14)
Hand-held Blender
IS 302 (Part 2/Sec 14):2009 0 82 ₹1,47,000
IS 302 (Part 2/Sec 9): 2009
Toasters, Grills, Roasters and Similar Appliances
IS 302 (Part 2/Sec 9):2009 2 115 ₹1,14,000
IS 302 (Part 2/Sec 31): 2009
Range Hoods
IS 302 (Part 2/Sec 31):2009 0 49 ₹1,65,000
IS 302 (Part 2/Sec 23): 2009
Appliances for Skin or Hair Care
IS 302 (Part 2/Sec 23):2009 1 54 ₹2,22,000
IS 302 (Part 2/ Sec 80): 2017
Fans
IS 302 (Part 2/Sec 80):2017 2 178 ₹1,54,000
IS 302 (Part 2/Sec 75): 2018
Commercial Dispensing Appliances and Vending Machines
IS 302 (Part 2/Sec 75):2018 0 17 ₹2,38,000
IS 302 (Part 2/Sec 7): 2010
Domestic Electric Clothes Washing Machines
IS 302 (Part 2/Sec 7):2024 0 42 ₹3,31,000
IS 302 (Part 2/Sec 21): 2018
Appliances for Stationary Storage Type Electric Water Heaters
IS 302 (Part 2/Sec 21):2024 1 28 ₹1,30,000
IS 302 (Part 2/Sec 35): 2017
Appliances for Electric Instantaneous Water Heaters
IS 302 (Part 2/Sec 35):2017 1 58 ₹1,04,000
IS 302 (Part 1) : 2024 IEC 60335-1:2020
All Electrical Appliances Vacuum Cleaners and Water Suction Cleaning Appliances
IS 302 (Part 1):2024 4 612 —
IS 302-2-76:1999
Electric Fence Energizers
IS 302 (Part 2/Sec 76):1999 0 43 ₹2,70,000
IS 302-2-25
Microwave Ovens
IS 302 (Part 2/Sec 25):2014 0 — —
IS 302-2:26
Mains-Powered Electronic Clocks
IS 302 (Part 2/Sec 26):2026 1 — —
IS 302 (Part 1): 2008
Adapters for Household Appliances
IS 302 (Part 1):2024 4 612 —
IS 302 (Part 2): Section 6: 2009
Induction Stove
IS 302 (Part 2/Sec 6):2009 0 — —
IS 302 (Part 2): Section 15: 2009
Rice Cooker
IS 302 (Part 2/Sec 15):2009 0 18 ₹1,58,000

Details by part

IS 302 (Part 2/Sec 3) Electric Iron

Editions and amendments of IS 302 (Part 2/Sec 3)

EditionPublishedStatus
IS 302 (Part 2/Sec 3):2024
Household and Similar Electrical Appliances Safety Part 2 Particular Requirements Section 3 Electric Irons (Second Revision)
5 Sept 2024Current, next review 30 Sept 2029
IS 302 (Part 2/Sec 3):2007
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision)
30 Jun 2007Current, next review 1 Mar 2027

BIS lists 2 current editions of IS 302 (Part 2/Sec 3). During a changeover both can be used until the date BIS sets for moving to the newer one.

Amendments:First Amendment (2013) to IS 302 (Part 2/Sec 3):2007. Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 3)

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 3), set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹73,000
Medium₹59,000
Small₹36,500
Micro₹14,600

Unit rate: ₹1.3 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 3)

From the BIS product manual for IS 302 (Part 2/Sec 3), which BIS officers and applicants follow for certification:

Sample quantity:4 number

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302 (Part 1))
  • Electric strength test (A-2 of IS 302 (Part 1))
  • Functional Test (A-3 of IS 302 (Part 1))
  • Marking (Cl. 7)
  • Protection Against Live Parts (Cl. 8)
  • Power Input and current (Cl. 10)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Provision for Earthing (C. 27)

The full type test covers every clause of IS 302 (Part 2/Sec 3); the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 3)

BIS records 160 operative licences (162 including deferred, cancelled or under stop marking). Most licensed factories are in Delhi (68), Himachal Pradesh (32), Haryana (28), Gujarat (10), Maharashtra (4).

IS 302 (Part 2/Sec 201) Electric Immersion Water-heaters

Editions and amendments of IS 302 (Part 2/Sec 201)

EditionPublishedStatus
IS 302 (Part 2/Sec 201):2008
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision)
31 May 2008Current, next review 31 May 2023

Amendments:First Amendment (2013). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 201)

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 201), set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹66,000
Medium₹53,000
Small₹33,000
Micro₹13,200

Unit rate: ₹1.3 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 201)

From the BIS product manual for IS 302 (Part 2/Sec 201), which BIS officers and applicants follow for certification:

Sample quantity:2 Nos. of electric immersion water heaters

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-2-7)
  • Electric strength test (A-2 of IS 302-2-7)
  • Functional test (A-3 of IS 302-2-7)
  • Marking and Instruction (Cl. 7)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Leakage current and Electric strength (Cl. 16)
  • Provision for earthing (Cl. 27)

The full type test covers every clause of IS 302 (Part 2/Sec 201); the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 201)

BIS records 60 operative licences (69 including deferred, cancelled or under stop marking). Most licensed factories are in Delhi (38), Haryana (11), Uttar Pradesh (5), Himachal Pradesh (4), Punjab (1).

IS 302 (Part 2/Sec 202) Electric Stoves

Editions and amendments of IS 302 (Part 2/Sec 202)

EditionPublishedStatus
IS 302 (Part 2/Sec 202):1992
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves
31 Mar 1992Current, next review 3 Oct 2029

Amendments:First Amendment (1993), Second Amendment (2002). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 202)

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 202), set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹75,000
Medium₹60,000
Small₹37,500
Micro₹15,000

Unit rate: ₹0.8 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 202)

From the BIS product manual for IS 302 (Part 2/Sec 202), which BIS officers and applicants follow for certification:

Sample quantity:2 nos. of Electric Stove

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (Cl. 5.1, A-1 of IS 302-1)
  • Electric strength test (Cl. 5.1, A-2 of IS 302-1)
  • Functional test (Cl. 5.1, A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 16)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Stability and Mechanical Hazards (Cl. 20)
  • Marking (Cl. 7)
  • Internal wiring (Cl. 23)
  • Terminals for external conductors (Cl. 26)

The full type test covers every clause of IS 302 (Part 2/Sec 202); the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 202)

BIS records 1 operative licences (1 including deferred, cancelled or under stop marking). Most licensed factories are in Uttar Pradesh (1).

IS 302 (Part 2/Sec 30) Room Heaters

Editions and amendments of IS 302 (Part 2/Sec 30)

EditionPublishedStatus
IS 302 (Part 2/Sec 30):2007
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision)
31 Aug 2007Current, next review 31 Dec 2029

Amendments:First Amendment (2012), Second Amendment (2019), Third Amendment (2023). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 30)

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 30), set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹85,000
Medium₹68,000
Small₹42,500
Micro₹17,000

Unit rate: ₹1.3 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 30)

From the BIS product manual for IS 302 (Part 2/Sec 30), which BIS officers and applicants follow for certification:

Sample quantity:2 nos. of Room Heaters

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (Cl. 5.1, A-1 of IS 302-1)
  • Electric strength test (Cl. 5.1, A-2 of IS 302-1)
  • Functional test (Cl. 5.1, A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 16)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)
  • Marking (Cl. 7)

The full type test covers every clause of IS 302 (Part 2/Sec 30); the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 30)

BIS records 115 operative licences (125 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (40), Delhi (30), Himachal Pradesh (14), Uttar Pradesh (14), Rajasthan (5).

IS 302 (Part 2/ Section 14) Hand-held Blender

Editions and amendments of IS 302 (Part 2/ Section 14)

EditionPublishedStatus
IS 302 (Part 2/Sec 14):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision)
31 Dec 2009Current, next review 31 Dec 2029

No amendments to the current edition are listed by BIS.

Marking fee for IS 302 (Part 2/ Section 14)

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/ Section 14), set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,47,000
Medium₹1,18,000
Small₹73,500
Micro₹29,400

Unit rate: ₹2 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/ Section 14)

From the BIS product manual for IS 302 (Part 2/ Section 14), which BIS officers and applicants follow for certification:

Sample quantity:2 numbers

Raw material requirements:

  • Components as per Cl. 24 of IS 302-2-14

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl. 8)
  • Earth Continuity Test (A-1 of IS 302-1)
  • Electric Strength Test (A-2 of IS 302-1)
  • Functional test (A-3 of IS 302-1)
  • Protection Against Electric Shock ( Cl. 8)
  • Power Input and Current (Cl. 10)
  • Electric Insulation and Leakage Current at Operating Temperature ( Cl. 13)
  • Provisions of Earthing ( Cl. 27)

The full type test covers every clause of IS 302 (Part 2/ Section 14); the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/ Section 14)

BIS records 82 operative licences (83 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (25), Maharashtra (11), Himachal Pradesh (9), Delhi (9), Uttar Pradesh (7).

IS 302 (Part 2/Sec 9): 2009 Toasters, Grills, Roasters and Similar Appliances

Editions and amendments of IS 302 (Part 2/Sec 9): 2009

EditionPublishedStatus
IS 302 (Part 2/Sec 9):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 9 toasters, grills, roasters and similar appliances (First Revision)
31 Dec 2009Current, next review 31 Dec 2029

Amendments:First Amendment (2002), Second Amendment (2005). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 9): 2009

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 9): 2009, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,14,000
Medium₹92,000
Small₹57,000
Micro₹22,800

Unit rate: ₹0.95 per no.. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 9): 2009

From the BIS product manual for IS 302 (Part 2/Sec 9): 2009, which BIS officers and applicants follow for certification:

Sample quantity:1 no.

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 9): 2009; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 9): 2009

BIS records 115 operative licences (119 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (41), Himachal Pradesh (15), Uttar Pradesh (12), Maharashtra (10), Delhi (9).

IS 302 (Part 2/Sec 31): 2009 Range Hoods

Editions and amendments of IS 302 (Part 2/Sec 31): 2009

EditionPublishedStatus
IS 302 (Part 2/Sec 31):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods
31 Dec 2010Current, next review 31 Dec 2029

No amendments to the current edition are listed by BIS.

Marking fee for IS 302 (Part 2/Sec 31): 2009

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 31): 2009, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,65,000
Medium₹1,32,000
Small₹82,500
Micro₹33,000

Unit rate: ₹3.3 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 31): 2009

From the BIS product manual for IS 302 (Part 2/Sec 31): 2009 (July 2026), which BIS officers and applicants follow for certification:

Sample quantity:1 no.

Raw material requirements:

  • Components as per Cl. 24 of IS 302 (Part 1)

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl.7)
  • Earth Continuity Test (A-1)
  • Electric Strength Test (A-2)
  • Functional test (A-3)
  • Protection against access to live parts (Cl. 8)
  • Power Input and Current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage Current and Electric Strength at operating temperature (Cl. 13)
  • Mechanical Strength (Cl.21)
  • Provision for Earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 31): 2009; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 31): 2009

BIS records 49 operative licences (51 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (16), West Bengal (5), Uttar Pradesh (4), Gujarat (3), Maharashtra (3).

IS 302 (Part 2/Sec 23): 2009 Appliances for Skin or Hair Care

Editions and amendments of IS 302 (Part 2/Sec 23): 2009

EditionPublishedStatus
IS 302 (Part 2/Sec 23):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision)
31 Dec 2009Current, next review 31 Dec 2029

Amendments:First Amendment (2024). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 23): 2009

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 23): 2009, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹2,22,000
Medium₹1,78,000
Small₹1,11,000
Micro₹44,400

Unit rate: ₹0.15 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 23): 2009

From the BIS product manual for IS 302 (Part 2/Sec 23): 2009, which BIS officers and applicants follow for certification:

Sample quantity:1 number

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 23): 2009; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 23): 2009

BIS records 54 operative licences (57 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (12), Delhi (11), Maharashtra (10), Uttar Pradesh (6), Gujarat (5).

IS 302 (Part 2/ Sec 80): 2017 Fans

Editions and amendments of IS 302 (Part 2/ Sec 80): 2017

EditionPublishedStatus
IS 302 (Part 2/Sec 80):2017
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision)
31 Jul 2017Current, next review 3 Oct 2029

Amendments:First Amendment (2023), Second Amendment (2025). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/ Sec 80): 2017

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/ Sec 80): 2017, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,54,000
Medium₹1,24,000
Small₹77,000
Micro₹30,800

Unit rate: ₹0.65 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/ Sec 80): 2017

From the BIS product manual for IS 302 (Part 2/ Sec 80): 2017 (July 2026), which BIS officers and applicants follow for certification:

Sample quantity:1 no.

Raw material requirements:

  • Stampings for fan motors as per IS 648 or any other suitable low loss electrical sheet steel
  • Insulation cords as per IS 694 or IS 9968 (Part 1)
  • Capacitors for fan motors as per IS 2993 (Part 1) or IS 2993 (Part 2)

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl.7)
  • Earth Continuity Test (A-1)
  • Electric Strength Test (A-2)
  • Functional test (A-3)
  • Protection against access to live parts (Cl. 8)
  • Power Input and Current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage Current and Electric Strength at operating temperature (Cl. 13)
  • Mechanical Strength (Cl.21)
  • Provision for Earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/ Sec 80): 2017; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/ Sec 80): 2017

BIS records 178 operative licences (184 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (34), Delhi (32), Uttar Pradesh (22), Telangana (20), Himachal Pradesh (15).

IS 302 (Part 2/Sec 75): 2018 Commercial Dispensing Appliances and Vending Machines

Editions and amendments of IS 302 (Part 2/Sec 75): 2018

EditionPublishedStatus
IS 302 (Part 2/Sec 75):2018
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines
31 Aug 2018Current, next review 31 Aug 2028

No amendments to the current edition are listed by BIS.

Marking fee for IS 302 (Part 2/Sec 75): 2018

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 75): 2018, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹2,38,000
Medium₹1,91,000
Small₹1,19,000
Micro₹47,600

Unit rate: ₹83.55 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 75): 2018

From the BIS product manual for IS 302 (Part 2/Sec 75): 2018 (June 2026), which BIS officers and applicants follow for certification:

Sample quantity:1 number.

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl. 7)
  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 75): 2018; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 75): 2018

BIS records 17 operative licences (18 including deferred, cancelled or under stop marking). Most licensed factories are in Karnataka (4), Haryana (4), Maharashtra (3), Tamil Nadu (2), Dadra & Nagar Haveli (1).

IS 302 (Part 2/Sec 7): 2010 Domestic Electric Clothes Washing Machines

Editions and amendments of IS 302 (Part 2/Sec 7): 2010

EditionPublishedStatus
IS 302 (Part 2/Sec 7):2024
Safety of Household And Similar Electrical Appliances Part 2 Particular Requirements Section 7: Domestic Electric Clothes Washing Machines
17 Jan 2024Current, next review 31 Jan 2029
IS 302 (Part 2/Sec 7):2010
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 7 domestic electric clothes washing machines (First Revision)
31 Mar 2010Withdrawn 9 Dec 2025

No amendments to the current edition are listed by BIS.

Marking fee for IS 302 (Part 2/Sec 7): 2010

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 7): 2010, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹3,31,000
Medium₹2,65,000
Small₹1,65,500
Micro₹66,200

Unit rate: ₹2 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 7): 2010

From the BIS product manual for IS 302 (Part 2/Sec 7): 2010, which BIS officers and applicants follow for certification:

Raw material requirements:

  • Components as per Cl. 24 of IS 302 (Part 2/ Sec 7)

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-2-7)
  • Electric strength test (A-2 of IS 302-2-7)
  • Functional test (A-3 of IS 302-2-7)
  • Marking and Instruction (Cl. 7)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Leakage current and Electric strength (Cl. 16)
  • Provision for earthing (Cl. 27)

The full type test covers every clause of IS 302 (Part 2/Sec 7): 2010; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 7): 2010

BIS records 42 operative licences (43 including deferred, cancelled or under stop marking). Most licensed factories are in Uttar Pradesh (13), Maharashtra (8), Uttarakhand (5), Andhra Pradesh (3), Haryana (3).

IS 302 (Part 2/Sec 21): 2018 Appliances for Stationary Storage Type Electric Water Heaters

Editions and amendments of IS 302 (Part 2/Sec 21): 2018

EditionPublishedStatus
IS 302 (Part 2/Sec 21):2024
Household and Similar Electrical AppliancesSafety Part 2 Particular Requirements Section 21 Storage Water Heaters
23 Aug 2024Current, next review 31 Aug 2029
IS 302 (Part 2/Sec 21):2018
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision)
31 Oct 2018Current, next review 31 Oct 2023

BIS lists 2 current editions of IS 302 (Part 2/Sec 21): 2018. During a changeover both can be used until the date BIS sets for moving to the newer one.

Amendments:First Amendment (2019) to IS 302 (Part 2/Sec 21):2018. Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 21): 2018

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 21): 2018, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,30,000
Medium₹1,04,000
Small₹65,000
Micro₹26,000

Unit rate: ₹6 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 21): 2018

From the BIS product manual for IS 302 (Part 2/Sec 21): 2018, which BIS officers and applicants follow for certification:

Sample quantity:2 numbers

Raw material requirements:

  • Components as per Cl. 24 of IS 302 (Part 2/ Sec 21)

Tests BIS can carry out in a day during factory inspection:

  • Pressure Test (Cl. 22.101, A.101)
  • Protection against access to live parts (Cl. 8)
  • High Voltage (Cl. 13.2.2 of IS 302 (Part 1))
  • Earthing Connection (Cl. 27)
  • Power Input and Current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage Current & Electric Strength at operating temperature (Cl. 13)
  • Leakage Current & Electric Strength (Cl. 16)
  • Mechanical Strength (Cl. 21)
  • Internal Wiring (Cl. 23)
  • Supply connections & external flexible cords (Cl. 25)
  • Terminals for external conductors (Cl. 26)
  • Provision for Earthing (Cl. 27)
  • Screws and Connections (Cl. 28)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 21): 2018; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 21): 2018

BIS records 28 operative licences (30 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (24), Maharashtra (4).

IS 302 (Part 2/Sec 35): 2017 Appliances for Electric Instantaneous Water Heaters

Editions and amendments of IS 302 (Part 2/Sec 35): 2017

EditionPublishedStatus
IS 302 (Part 2/Sec 35):2017
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision)
31 Dec 2017Current, next review 31 Dec 2029

Amendments:First Amendment (2019). Test reports must reflect the standard with its amendments.

Marking fee for IS 302 (Part 2/Sec 35): 2017

BIS charges an annual minimum marking fee for the ISI mark under IS 302 (Part 2/Sec 35): 2017, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹1,04,000
Medium₹84,000
Small₹52,000
Micro₹20,800

Unit rate: ₹2.6 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

Sampling and key tests for IS 302 (Part 2/Sec 35): 2017

From the BIS product manual for IS 302 (Part 2/Sec 35): 2017, which BIS officers and applicants follow for certification:

Sample quantity:2 no.

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2/Sec 35): 2017; the list above is what can be checked on site.

ISI licences under IS 302 (Part 2/Sec 35): 2017

BIS records 58 operative licences (62 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (23), Maharashtra (9), Himachal Pradesh (5), Delhi (5), Uttar Pradesh (4).

IS 302 (Part 1) : 2024 IEC 60335-1:2020 All Electrical Appliances Vacuum Cleaners and Water Suction Cleaning Appliances

Editions and amendments of IS 302 (Part 1) : 2024 IEC 60335-1:2020

EditionPublishedStatus
IS 302 (Part 1):2024
Household and Similar Electrical Appliances Safety Part 1 General Requirements (Seventh Revision)
5 Sept 2024Current, next review 30 Sept 2029
IS 302 (Part 1):2008
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision)
31 Aug 2008Current, next review 31 Jan 2021

BIS lists 2 current editions of IS 302 (Part 1) : 2024 IEC 60335-1:2020. During a changeover both can be used until the date BIS sets for moving to the newer one.

Amendments:First Amendment (2009) to IS 302 (Part 1):2008, Second Amendment (2013) to IS 302 (Part 1):2008, Third Amendment (2014) to IS 302 (Part 1):2008, Fourth Amendment (2015) to IS 302 (Part 1):2008. Test reports must reflect the standard with its amendments.

Sampling and key tests for IS 302 (Part 1) : 2024 IEC 60335-1:2020

From the BIS product manual for IS 302 (Part 1) : 2024 IEC 60335-1:2020 (October 2026), which BIS officers and applicants follow for certification:

Sample quantity:Where the samples are bulky and testing can be

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl.7)
  • Earth Continuity Test (A-2 of IS 302(Part 1))
  • Electric Strength Test (A-3 of IS 302(Part 1))
  • Functional test (A-4 of IS 302(Part 1))
  • Protection against access to live parts (Cl. 8)
  • Power Input and Current (Cl. 10)
  • Leakage Current and Electric Strength at operating temperature (Cl. 13)
  • Mechanical Strength (Cl.21)
  • Provision for Earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 1) : 2024 IEC 60335-1:2020; the list above is what can be checked on site.

ISI licences under IS 302 (Part 1) : 2024 IEC 60335-1:2020

BIS records 612 operative licences (640 including deferred, cancelled or under stop marking). Most licensed factories are in Haryana (112), Maharashtra (80), Tamil Nadu (80), Uttar Pradesh (76), Gujarat (44).

IS 302-2-76:1999 Electric Fence Energizers

Editions and amendments of IS 302-2-76:1999

EditionPublishedStatus
IS 302 (Part 2/Sec 76):1999
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 76 electric fence energizers
31 Dec 1999Current, next review 31 Dec 2029

No amendments to the current edition are listed by BIS.

Marking fee for IS 302-2-76:1999

BIS charges an annual minimum marking fee for the ISI mark under IS 302-2-76:1999, set by unit size, plus a per-unit rate once production passes the minimum:

Unit sizeMinimum marking fee (per year)
Large₹2,70,000
Medium₹2,16,000
Small₹1,35,000
Micro₹54,000

Unit rate: ₹12 per piece. Source: BIS marking fee schedule for Scheme-I products, September 2026.

ISI licences under IS 302-2-76:1999

BIS records 43 operative licences (43 including deferred, cancelled or under stop marking). Most licensed factories are in Gujarat (38), Kerala (1), Telangana (1), Tamil Nadu (1), Haryana (1).

IS 302-2-25 Microwave Ovens

Editions and amendments of IS 302-2-25

EditionPublishedStatus
IS 302 (Part 2/Sec 25):2014
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens
31 May 2014Current, next review 31 Jan 2030

No amendments to the current edition are listed by BIS.

IS 302-2:26 Mains-Powered Electronic Clocks

Editions and amendments of IS 302-2:26

EditionPublishedStatus
IS 302 (Part 2/Sec 26):2026
Household and Similar Electrical Appliances —— Safety Part 2 Particular Requirements Section 26 Clocks (Second Revision)
24 Jul 2026Current, next review 24 Jul 2031
IS 302 (Part 2/Sec 26):2014
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision)
31 Mar 2014Current, next review 31 Jan 2030

BIS lists 2 current editions of IS 302-2:26. During a changeover both can be used until the date BIS sets for moving to the newer one.

Amendments:First Amendment (2002) to IS 302 (Part 2/Sec 26):2014. Test reports must reflect the standard with its amendments.

IS 302 (Part 1): 2008 Adapters for Household Appliances

Editions and amendments of IS 302 (Part 1): 2008

EditionPublishedStatus
IS 302 (Part 1):2024
Household and Similar Electrical Appliances Safety Part 1 General Requirements (Seventh Revision)
5 Sept 2024Current, next review 30 Sept 2029
IS 302 (Part 1):2008
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision)
31 Aug 2008Current, next review 31 Jan 2021

BIS lists 2 current editions of IS 302 (Part 1): 2008. During a changeover both can be used until the date BIS sets for moving to the newer one.

Amendments:First Amendment (2009) to IS 302 (Part 1):2008, Second Amendment (2013) to IS 302 (Part 1):2008, Third Amendment (2014) to IS 302 (Part 1):2008, Fourth Amendment (2015) to IS 302 (Part 1):2008. Test reports must reflect the standard with its amendments.

Sampling and key tests for IS 302 (Part 1): 2008

From the BIS product manual for IS 302 (Part 1): 2008 (October 2026), which BIS officers and applicants follow for certification:

Sample quantity:Where the samples are bulky and testing can be

Tests BIS can carry out in a day during factory inspection:

  • Marking (Cl.7)
  • Earth Continuity Test (A-2 of IS 302(Part 1))
  • Electric Strength Test (A-3 of IS 302(Part 1))
  • Functional test (A-4 of IS 302(Part 1))
  • Protection against access to live parts (Cl. 8)
  • Power Input and Current (Cl. 10)
  • Leakage Current and Electric Strength at operating temperature (Cl. 13)
  • Mechanical Strength (Cl.21)
  • Provision for Earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 1): 2008; the list above is what can be checked on site.

IS 302 (Part 2): Section 6: 2009 Induction Stove

Editions and amendments of IS 302 (Part 2): Section 6: 2009

EditionPublishedStatus
IS 302 (Part 2/Sec 6):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision)
31 Dec 2009Current, next review 31 Dec 2029

No amendments to the current edition are listed by BIS.

Sampling and key tests for IS 302 (Part 2): Section 6: 2009

From the BIS product manual for IS 302 (Part 2): Section 6: 2009, which BIS officers and applicants follow for certification:

Sample quantity:1 no.

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Heating (Cl. 11)
  • Leakage current and electric strength at operating temperature (Cl. 13)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Resistance to heat and fire (Cl. 30)
  • Stability and Mechanical Hazards (Cl. 20)

The full type test covers every clause of IS 302 (Part 2): Section 6: 2009; the list above is what can be checked on site.

IS 302 (Part 2): Section 15: 2009 Rice Cooker

Editions and amendments of IS 302 (Part 2): Section 15: 2009

EditionPublishedStatus
IS 302 (Part 2/Sec 15):2009
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision)
31 Dec 2009Current, next review 31 Dec 2029

No amendments to the current edition are listed by BIS.

Sampling and key tests for IS 302 (Part 2): Section 15: 2009

From the BIS product manual for IS 302 (Part 2): Section 15: 2009, which BIS officers and applicants follow for certification:

Sample quantity:3 numbers

Tests BIS can carry out in a day during factory inspection:

  • Earth Continuity test (A-1 of IS 302-1)
  • Electric strength test (A-2 of IS 302-1)
  • Functional test (A-3 of IS 302-1)
  • Marking (Cl. 7)
  • Protection against access to live parts (Cl. 8)
  • Power input and current (Cl. 10)
  • Leakage current and electric strength (Cl. 16)
  • Mechanical strength (Cl. 21)
  • Provision for earthing (Cl. 27)
  • Screws and connections (Cl. 28)
  • Creepage distances, clearances and distances (Cl. 29)
  • Stability and Mechanical Hazards (Cl. 20)
  • Temperature rise (Cl. 17)

The full type test covers every clause of IS 302 (Part 2): Section 15: 2009; the list above is what can be checked on site.

Notifying orders

  • Electrical Wires, Cables, Appliances and Protection Devices and Accessories (Quality Control) Order, 2003, No. 189(E), dated 17 Feb 2003 · PDF
  • Bureau of Indian Standards Kitchen Appliances (Quality Control) Order, 2018, S.O. 5243(E), dated 10th October, 2018 · PDF
  • Electrical Appliances for Kitchen (Quality Control) Order, 2023, S.O. 1128(E), dated 05th March 2024 · PDF
  • Electrical Appliances for Skin or Hair care (Quality Control) Order, 2023, S.O. 1125(E), dated 05th March 2024 · PDF
  • Electrical appliance fans (Quality Control) Order, 2023, S.O. 1124(E), dated 05th March 2024 · PDF
  • Electrical appliance for commercial dispensing and vending (Quality Control) Order, 2023, S.O. 1127(E), dated 05th March 2024 · PDF
  • Electrical appliance for domestic clothes washing (Quality Control) Order, 2023, S.O. 1126(E), dated 05th March 2024 · PDF
  • Electrical Appliances for domestic water heating (Quality Control) Order, 2023, S.O. 1253(E), dated 05th March 2024 · PDF

How to get an ISI mark licence under IS 302

The licence is granted to the manufacturer for a specific factory and product. Indian factories apply under Scheme-I; overseas factories apply under the Foreign Manufacturers Certification Scheme (FMCS) and must nominate an Authorised Indian Representative.

  1. Confirm the exact Indian Standard and the varieties to cover
  2. Get the product tested at a BIS-recognised lab (simplified procedure) or arrange BIS sampling
  3. Apply on Manak Online with factory, quality-control and test documents
  4. BIS factory inspection and sample verification
  5. Grant of licence, then marking with the ISI mark and CM/L number

Timeline. BIS targets 30 days under the simplified procedure (applying with a recent lab test report) and 90 days under the normal procedure. Overseas factories under FMCS typically take around 6 months.

Fees. Application fee ₹1,000 and annual licence fee ₹1,000, inspection charges of ₹7,000 per man-day, testing charges, and an annual minimum marking fee set for each Indian Standard (with concessions for micro and small units).

Mark. Certified products carry the ISI Standard Mark with the IS number and the CM/L-XXXXXXXXXX licence number.

How to get CRS registration under IS 302

Registration is granted to the manufacturer for a specific factory, brand and models. Overseas manufacturers must appoint an Authorised Indian Representative to apply and hold the registration in India.

  1. Confirm the Indian Standard and group models into a series
  2. Submit samples to a BIS-recognised lab in India for testing
  3. Apply on the CRS portal with the test report, factory and brand documents
  4. BIS review and grant of the R-number registration
  5. Mark products with the Standard Mark, IS number and R-number

Timeline. Lab testing usually takes 2 to 6 weeks; BIS processing typically takes another 3 to 6 weeks after a complete application with the test report.

Fees. Application and annual licence fees of ₹1,000 each, a processing fee of ₹25,000 per year, and ₹20,000 for each additional test report, plus lab testing charges (BIS Conformity Assessment Amendment Regulations, 2026).

Mark. Certified products carry the BIS Standard Mark (CRS) with the IS number and the R-number.

Frequently asked questions

Is BIS certification mandatory for products under IS 302?

Yes, for the 20 products listed on this page. Each is notified by a government order and needs an ISI mark licence or CRS registration (depending on the product) before it can be made, imported or sold in India. Other products that merely use IS 302 are not automatically covered.

Which part of IS 302 applies to my product?

IS 302 has 20 parts or editions referenced in BIS orders. Find your product in the table above to see its exact part. Where a product is covered by more than one standard, all of them apply.

How long does ISI mark under IS 302 take?

BIS targets 30 days under the simplified procedure (applying with a recent lab test report) and 90 days under the normal procedure. Overseas factories under FMCS typically take around 6 months.

How long does CRS registration under IS 302 take?

Lab testing usually takes 2 to 6 weeks; BIS processing typically takes another 3 to 6 weeks after a complete application with the test report.

Other standards in Household Electrical goods

  • IS 368 Electric Immersion Water Heaters
  • IS 418 Tungsten Filament General Service Electric Lamps (upto100 W )
  • IS 694 PVC Insulated Cables for Working Voltages up to and Including 1100V
  • IS 2082 Stationary Storage Type Electric Water Heaters
  • IS 3854 Switches for Domestic and Similar Purposes
  • IS 4250 Domestic Electric Food Mixer (Liquidizers and Grinders) and Centrifugal Juicer
  • IS 8828 Electrical Accessories-Circuit Breakers for Overcurrent Protection for Household and Similar Installations
  • IS 9968 2 products
  • IS 10322 8 products
  • IS 12640 2 products

Source: BIS lists of products under compulsory certification (Scheme-I, Scheme-II), checked October 2026. See the full BIS product list or all Indian Standards.

Not sure which certification your product needs?

Talk to a team led by former BIS Directors. We'll map every approval your product needs before you spend on testing.

Call WhatsApp Get a quote