Since 1 April 2026, a CCTV camera that is not analog cannot be sold in India unless it meets MeitY’s Essential Requirement(s) for Security of CCTV. BIS calls this requirement ER 01. The camera is tested at one of 14 STQC laboratories, and the passing models are added to the manufacturer’s BIS CRS registration alongside the electrical safety standard. The rule itself is not new: MeitY notified it on 9 April 2024, and it took effect on 9 April 2025. What changed in 2026 is that the last relaxation, for old stock, was withdrawn.
CCTV security requirements at a glance
| Question | Answer | Source |
|---|---|---|
| What is required? | 30 security test clauses in four groups: hardware, software and firmware, secure process, and product development | S.O. 1652(E), 9 April 2024 |
| Which products? | CCTV cameras other than analog: IP, Wi-Fi and 4G cameras | S.O. 1652(E); BIS circular of 1 April 2025 |
| Since when? | 9 April 2025 for registration; 1 April 2026 for every sale, old stock included | S.O. 4378(E); MeitY OM of 16 January 2026 |
| Who tests? | 14 STQC laboratories recognised by BIS for ER 01 | BIS circular of 25 November 2024; BIS LIMS |
| Who registers? | BIS, under the Compulsory Registration Scheme (CRS), on the same R-number as the safety registration | BIS guideline of 22 October 2024 |
| Safety standard | IS/IEC 62368-1:2023, or IS 13252 (Part 1):2010 until 1 November 2028 | S.O. 4997(E), 29 October 2025 |
| Testing charges | Rs 2 lakh to Rs 3.245 lakh per test report, before GST | BIS LIMS, 26 November 2026 |
| BIS fee | Rs 30,000 per application, including one test report, plus Rs 20,000 per extra report, before taxes | BIS guideline of 22 October 2024 |
Timeline: how the rule came in
| Date | Document | What it did |
|---|---|---|
| 6 March 2024 | MeitY S.O. 1119(E), under the Public Procurement (Preference to Make in India) Order | Required CCTV cameras bought by government bodies to meet the same security requirements, tested by STQC, and set local content rules |
| 9 April 2024 | MeitY S.O. 1652(E) | Added the Essential Requirement(s) for Security of CCTV to item 41, CCTV Camera, of the Compulsory Registration Order, effective six months later |
| 9 October 2024 | MeitY S.O. 4378(E) | Moved the effective date from 9 October 2024 to 9 April 2025 because industry asked for more time |
| 22 October 2024 | BIS guideline | Set the steps for licensees and new applicants, the fees and MeitY’s series guidelines; opened the ER: 01 test request on the BIS portal |
| 25 November 2024 | BIS circular | Recognised 14 STQC labs and accepted test reports they had already issued for government procurement |
| 12 March 2025 | MeitY notification, cited by BIS | Clarified that the security requirements do not apply to analog CCTV cameras |
| 9 April 2025 | Effective date | No new registration without ER 01; non-compliant models deleted from existing licences |
| 21 May 2025 | MeitY OM W-43/11/2021-IPHW | Allowed sale of cameras made or imported before 9 April 2025, to clear existing stock |
| 16 January 2026 | MeitY OM W-18/26/2025-IPHW | Withdrew that relaxation from 1 April 2026 |
| 1 April 2026 | Sale ban in force | No sale of any CCTV camera that does not conform to the requirements |
The 16 January 2026 memo is two paragraphs long. It says the relaxation “shall stand withdrawn” from 1 April 2026, and that from then no CCTV camera that does not conform to the requirements may be sold. It does not ban imports or foreign brands. A camera made abroad can still be sold if its model has passed ER 01 and is on its R-number.
What the security requirements test
The annexure to S.O. 1652(E) lists five principles: physical tamper resistance, access control by authentication and role-based access, encryption of data in transit, software security through updates, disabled unused features and strong passwords, and penetration testing. These are then set out as 30 test clauses in four groups. For each clause it says what the lab tests and which documents the manufacturer must give.
| Group | Clauses | What is checked |
|---|---|---|
| 1. Hardware level security | 1.1 to 1.9 | USB and UART debug ports and on-chip JTAG or SWD disabled or password-protected; cryptographic keys unique to each device; trusted execution environment, secure element or TPM used where the SoC has one; keys and sensitive data stored securely; tamper resistance or detection; the chip maker’s IP protection enabled; secure boot that rejects a tampered image; a cryptographically secure random number generator |
| 2. Software and firmware | 2.1 to 2.12 | Memory protection such as ASLR and DEP; TLS for data in transit, with proper certificate validation, checked with tools such as Nmap and Burp Suite; certificate pinning to trusted servers; no banned C functions; a software bill of materials with third-party components and known vulnerabilities; code review for hardcoded credentials (backdoors); protection against firmware reverse engineering; signed firmware updates; anti-rollback; automatic or documented manual updates |
| 3. Secure process | 3.1 to 3.5 | Mutual authentication and encryption on wireless links; a managed bill of materials for security-critical parts such as the SoC; supply chain risk and business continuity documents; source code for any proprietary network protocol |
| 4. Product development | 4.1 to 4.4 | Design and architecture down to PCBA and SoC level; counterfeit and tainted-component controls; malware scanning in development and before packing; supply chain risk assessment |
The code review clauses need the firmware source. The notification gives the manufacturer four options. They can bring the code to the lab and run the lab’s licensed static analysis tool (the option it recommends), demonstrate their own tool there, or give the lab remote access, either to install its tool or to use the manufacturer’s. Many clauses are tested “in presence of OEM team”, so plan for engineers to be at the lab.
What the lab looks for on supply chain
STQC’s guidance to its labs on clauses 3.3, 3.4, 4.1 and 4.2 goes further than the notification’s text. It names the security-critical parts as the SoC, firmware, PCBA, network interface card and physical interfaces. It asks for the PCBA design document, layout diagram and X-ray images, invoices for the SoC and firmware (unless made in-house), and traceability from purchase to final assembly. It also asks labs to verify that the SoC and firmware are not sourced from countries that share a land border with India.
That guidance cites the March 2024 procurement notification. It does not say whether a lab applies the land-border check in a test for BIS registration only. Ask the lab before you send samples, and keep the invoices and design files ready either way.
Which cameras are covered
- IP, Wi-Fi and 4G cameras: covered. The notification covers item 41, CCTV Camera, and its test clauses assume a networked device with firmware and network services. Home Wi-Fi cameras sold online are CCTV cameras for this purpose.
- Analog cameras: not covered. BIS’s circular of 1 April 2025 records MeitY’s clarification of 12 March 2025. Analog models still need CRS registration to the safety standard. Licensees listed their analog models by self-declaration, and every new test report must say whether each model is analog. Analog and other cameras cannot go in one application.
- DVRs and NVRs: safety registration only. Item 41 of the order is “CCTV Cameras/CCTV Recorders”, but S.O. 1652(E) adds the security requirements for the camera only. MeitY’s procurement notification said norms for DVRs and NVRs “will be notified subsequently”. We have not found such a notification as of November 2026.
For a video door phone, MeitY’s CRS FAQs treat the monitor, outdoor camera unit and adaptor as separate CRS products. Whether the outdoor unit needs ER 01 depends on whether it is a networked camera, so check with the lab before testing.
Who tests, and what it costs
BIS’s circular of 25 November 2024 recognised 14 STQC laboratories for ER 01. On 26 November 2026, BIS LIMS still listed the same 14, and no private laboratory:
| Laboratory | Charges for all clauses, before GST |
|---|---|
| ETDC Chennai; ERTL (West) Mumbai | Rs 2,00,000 |
| ETDC Pune, Thiruvananthapuram, Mohali, Jaipur, Ajmer, Solan, Goa, Guwahati and Bengaluru; ERTL (North) Delhi | Rs 2,75,000 |
| ETDC Agartala | Rs 2,75,010 |
| ETDC Hyderabad | Rs 3,24,500 |
LIMS prices each of the 30 clauses separately, for example Rs 6,666 a clause at Chennai and Rs 9,167 at Pune. A test report covers one lead model and its series. The safety test to IS/IEC 62368-1:2023 is separate and can be done at any BIS-recognised lab for that standard.
Series: how many models one report covers
MeitY’s series guidelines for CCTV, attached to the BIS guideline, are stricter than the older CRS series rules for cameras. Models in one series must have:
- the same SoC;
- the same PCBA layout for security-related circuits (housing, lens, mount, connectors and interface boards may differ);
- the same wired and wireless protocols, with the model that has the most features tested;
- the same firmware version, down to the build number, with matching hash values; a second firmware version is a separate series;
- the same hardware bill of materials, except passive parts such as image sensors, lenses, resistors, capacitors, power driver ICs, ADCs, DACs and RAM that do not affect security;
- a complete software bill of materials.
The report and certificate record a product photo, model number, chipset make, model and country of origin, firmware version and hash. STQC also asks for a differential analysis report comparing each series model with the tested one.
How to get ER 01 added to a BIS registration
Existing licensee:
- Generate a test request for “Essential Requirement(s) for Security of CCTV: ER 01” on the BIS portal and send the lead model to an STQC lab.
- Apply online through the “Apply for Standard Revision/ Amendment/ Essential Requirement” module with the ER 01 report. Do not use the inclusion module for models already registered.
- Pay Rs 30,000 plus taxes per application, including one report, and Rs 20,000 plus taxes for each further report.
- BIS issues a letter listing the models that comply. Models without it were deleted from licences after 9 April 2025, and a licence with no compliant model is liable to cancellation.
New applicant or new model (inclusion): submit the ER 01 report together with the safety report. Since 9 April 2025, BIS grants no registration or inclusion for a non-analog camera without ER 01. The rest follows the normal CRS registration process, including an Authorised Indian Representative for a foreign manufacturer.
Compliant models may carry the statement “This CCTV camera complies with Essential Requirement(s) for Security” on the packaging. BIS allows this; it does not require it. The Standard Mark with the R-number is still required on the product and packaging.
The full BIS guideline is summarised on our page for the BIS CCTV security guidelines, with copies of the circulars.
BIS registration (CRO) and STQC certification (PPO) are different
People mix up two schemes that use the same requirements and the same labs:
| BIS registration under the CRO | STQC IoTSCS certification under the PPO | |
|---|---|---|
| Needed for | Any sale, import or manufacture for sale in India | Supplying CCTV to government buyers under the Public Procurement (Preference to Make in India) Order |
| Legal basis | S.O. 1652(E), 9 April 2024 | S.O. 1119(E), 6 March 2024 |
| What you get | Compliant models listed on the BIS R-number | STQC certificate of approval, valid three years, subject to surveillance |
| Extra checks | None beyond the ER 01 test | Technical construction file, a validator appointed by STQC, ISO 9001 certificates, and local content rules for procurement preference |
BIS accepts STQC test reports already issued for the procurement scheme (circular of 25 November 2024). The reverse is harder. STQC’s letter of 18 December 2025 says CRO test reports are not validated, so a model tested for BIS only may need fresh validation or more testing for procurement later. STQC labs now ask every CRO applicant for an undertaking on whether they intend to apply under the procurement scheme. If government tenders are likely, say so at the start and test once.
How to check whether a camera complies
BIS publishes a List of Registrations and models of CCTVs complying with ER for Security on crsbis.in. Each row is an R-number, with the compliant models and the analog models in separate columns.
On 26 November 2026 the list had 90 R-numbers. 64 of them had models that comply with the security requirements, 1,120 models in all, and the other 26 listed analog models only. 50 of the 64 manufacturers with compliant models are in India. The rest are in Taiwan, South Korea, Japan, Vietnam, Thailand, Cambodia, Portugal, Poland and Mexico. The five registrations of manufacturers in China listed analog models only.
To check a particular camera, find its R-number on the product or box, then look for the exact model in the compliant column. A model that is not there, and not analog, cannot be sold. To look up the registration itself, see how to check a BIS R-number.
What this means if you sell cameras
- Traders and online sellers: old stock made or imported before 9 April 2025 can no longer be sold unless its model is on the compliant list. Check model numbers, not just the brand, because one brand often has compliant and non-compliant models on the same R-number.
- Importers: the overseas factory needs ER 01 on its own R-number. Allow time for STQC testing with factory engineers present, source code review and supply chain documents. Collect SoC and firmware invoices and the PCBA design files before testing.
- Brands with several firmware builds: each firmware version is a separate series. Freeze the build before testing, because changing it later means a new report.
- Firmware updates after registration: the series rule ties the registration to the tested firmware version and hash. MeitY’s documents don’t say how later updates are handled, so ask BIS or the lab before releasing a new build.
Other approvals a CCTV camera needs
- Safety: CRS registration to IS/IEC 62368-1:2023. S.O. 4997(E) moved CCTV equipment from IS 13252 (Part 1) to the new standard, with the old one accepted until 1 November 2028. The security requirements stay as a second requirement after the move; see the migration guideline.
- Wi-Fi and Bluetooth: WPC Equipment Type Approval, by self-declaration on the Saral Sanchar portal with an RF test report.
- E-waste: the producer needs EPR registration with CPCB under the E-Waste (Management) Rules, 2022; see EPR for CCTV cameras and recorders.
- Adaptor: a power adaptor supplied with the camera needs its own CRS registration.
How Aaditech can help
Aaditech prepares CCTV makers and importers for ER 01. We check the model list for analog and network cameras, group models into series under MeitY’s stricter rules, and assemble the documents the labs ask for: the SoC datasheet, key management lifecycle, SBOM, PCBA design and supply chain files. We also book the STQC lab. Our team, which includes former BIS Directors, then files the ER application on the existing licence or a new CRS registration with the safety report, along with WPC ETA and e-waste EPR. For the wider picture, see BIS for electronics and IT products.