BIS Guidelines for Implementation of Essential Requirement(s) for Security of CCTV (October 2024)

How CCTV camera licensees and applicants add MeitY's security Essential Requirements (ER 01) to a CRS registration, in force since 9 April 2025 and for every sale since 1 April 2026.

Issued byBureau of Indian Standards, Registration Department
ReferenceRegistration/Meity/ CCTV Camera
Edition22 October 2024
Length4 pages, PDF
StatusIn force, read with the later circulars below: ER 01 has applied to registrations since 9 April 2025, analog cameras are exempt, and since 1 April 2026 no non-conforming CCTV camera may be sold.
Official copycrsbis.in
Our copyDownload PDF, saved from the official source

Changed by later circulars

  • 25 November 2024: Acceptance of test reports issued under the Public Procurement Order (PPO) (Registration/Meity/CCTV)

    BIS has recognised 14 STQC laboratories for the security requirements. Test reports they issued under the procurement scheme, including for samples received before their recognition, can be attached to a LIMS test request and used for BIS without further testing.

    PDF Official
  • 1 April 2025: Non-applicability of security ER to analog CCTV cameras (Registration/Meity/CCTV)

    MeitY clarified on 12 March 2025 that the security requirements do not apply to analog CCTV cameras. Licensees list analog models by self-declaration, test reports must state whether each model is analog, and analog and other cameras cannot be combined in one application.

    PDF Official
  • 16 January 2026: MeitY OM: withdrawal of extension for compliance with ERs for security of CCTV cameras (W-18/26/2025-IPHW)

    MeitY withdrew, from 1 April 2026, the relaxation of 21 May 2025 that allowed sale of CCTV cameras made or imported before 9 April 2025. From 1 April 2026 no CCTV camera that does not conform to the security requirements may be sold.

    PDF Official

What this document is

CCTV cameras and recorders are item 41 of MeitY’s Electronics and Information Technology Goods (Requirements for Compulsory Registration) Order, 2021, registered under Scheme II of the BIS (Conformity Assessment) Regulations, 2018. On 9 April 2024 MeitY added a second requirement for CCTV cameras: the Essential Requirement(s) for Security of CCTV, by S.O. 1652(E). The order was to apply six months later. S.O. 4378(E) of 9 October 2024 moved that to 9 April 2025.

On 22 October 2024 the BIS Registration Department issued this guideline to put the requirement into effect. It opened the ER: 01 test request on the BIS portal and attached MeitY’s series guidelines for CCTV. Test reports come from third-party laboratories, and BIS has recognised 14 STQC laboratories for them. Each lead model needs a report that names the series models it covers, with their similarities, differences and hardware and software bills of materials.

The safety standard in the guideline is IS 13252 (Part 1):2010. CCTV equipment has since been moved to IS/IEC 62368-1:2023, and the security requirements stay alongside it; see the migration guideline.

Key dates

  • 9 April 2024: S.O. 1652(E) notifies the security requirements.
  • 22 October 2024: this guideline; ER: 01 test requests open.
  • 25 November 2024: 14 STQC labs recognised; procurement-scheme reports accepted.
  • 1 April 2025: BIS circular on analog cameras, after MeitY’s clarification of 12 March 2025.
  • 9 April 2025: no registration or inclusion without ER 01; non-compliant models deleted.
  • 21 May 2025: MeitY allows sale of stock made or imported before 9 April 2025.
  • 1 April 2026: that relaxation ends (MeitY OM of 16 January 2026).

Existing licensees

  1. Implement the requirement for the models already in the licence by applying online through the “Apply for Standard Revision/ Amendment/ Essential Requirement” module, with the ER 01 test report.
  2. Pay the fee for an extension of scope: Rs 30,000 plus taxes per application, including one test report, and Rs 20,000 plus taxes for each further report.
  3. BIS issues a letter listing every model for which compliance is established.
  4. After 9 April 2025, non-compliant models are deleted from the scope. If the licensee does nothing, or no model complies, the licence is liable to cancellation.
  5. Do not use the inclusion module to add the requirement for registered models.

Under the analog circular, licensees also listed their analog models through the same module by self-declaration, without a test report.

New applicants and inclusions

  • Applications and inclusions are submitted with the ER 01 report as well as the safety report.
  • Applications without ER 01 were processed only up to 9 April 2025, with a declaration to comply by then.
  • Since 9 April 2025, no licence or inclusion for a CCTV camera is granted without the security requirements, except for analog models.
  • Analog models are applied with the safety report only. Analog and other cameras cannot be combined in one application or inclusion ID.

Series guidelines for CCTV

The attached MeitY series guidelines apply to both BIS registration and STQC’s procurement certification. Models in one series must share the SoC, the PCBA layout of security-related circuits, the wired and wireless protocols and the exact firmware version and hash. The hardware bill of materials must be the same apart from passive parts such as image sensors, lenses, resistors, capacitors and RAM that do not affect security. The software bill of materials must list every firmware, open-source, operating system and third-party component. The certificate records the product photo, model number, chipset make, model and country of origin, firmware version and hash.

Labelling

Compliant models may display on the packaging: “This CCTV camera complies with Essential Requirement(s) for Security”. The guideline permits this; it does not make it compulsory.

Status

The guideline is in force, read with the later circulars above. BIS publishes the list of registrations and models complying with ER for Security on crsbis.in. For the test clauses, lab fees and the difference between BIS registration and STQC procurement certification, see our guide to CCTV security requirements and STQC testing.

Products this document applies to

Each product page shows the Indian Standard, the notifying order and how to register.

Frequently asked questions

What is ER 01?

BIS's code for MeitY's Essential Requirement(s) for Security of CCTV, notified by S.O. 1652(E) on 9 April 2024 for item 41 of the Compulsory Registration Order. The BIS portal generates test requests under 'Essential Requirement(s) for Security of CCTV – ER: 01', and LIMS lists the recognised labs under ER 01 (2024).

How do existing licensees add the security requirements?

Through the 'Apply for Standard Revision/ Amendment/ Essential Requirement' module, with an ER 01 test report for each lead model. The fee is Rs 30,000 plus taxes per application, including one test report, and Rs 20,000 plus taxes for each additional report. BIS then issues a letter listing the compliant models.

What happened to models that did not comply by 9 April 2025?

They were to be deleted from the scope of the licence. A licence with no compliant model is liable to cancellation. Analog models listed by self-declaration stay, because the security requirements do not apply to them.

Can old CCTV stock still be sold?

Not unless the model complies. MeitY's OM of 21 May 2025 allowed sale of cameras made or imported before 9 April 2025, but its OM of 16 January 2026 withdrew that relaxation from 1 April 2026.

More in Product standards

Also on our CRS guidelines page: Series guidelines · CRS FAQs · IS/IEC 62368-1:2023 migration · Solar PV

All CRS guidelines and FAQs

Related guides from our team

This page is our summary of an official document, written for general guidance. The PDF is the authoritative text. BIS and MeitY revise these documents from time to time, so check the official source or speak to our team before acting. Published 22 October 2024.

Planning a CRS registration?

We group your models, choose the lead models and file on the CRS portal, so testing runs once.

Call WhatsApp Get a quote