MNRE Series Guidelines for Solar Storage Batteries, IS 16270 (Draft, 2025)

How lithium-ion, lead-acid and nickel solar batteries are grouped into series by rated capacity for IS 16270:2023 testing, with the highest rating tested in full.

Issued byMinistry of New and Renewable Energy (MNRE), Standards and Quality Control Division
ReferenceFile No. 313-12/10/2025-S AND QC
EditionDraft for comments, September 2025
Length9 pages, PDF
StatusCirculated by MNRE as a draft for comments in September 2025. We have not found a final version. The final guidelines of 27 June 2019, under the 2017 order, covered only lead-acid and nickel batteries.
Official copycdnbbsr.s3waas.gov.in
Our copyDownload PDF, saved from the official source

What this document is

Solar storage batteries are registered with BIS under IS 16270:2023 and MNRE’s Solar Systems, Devices and Components Goods Order, 2025 (S.O. 492(E)). MeitY’s CRS series guidelines do not apply to them. MNRE sets its own rules for grouping models into a series, so that one set of type tests covers a family of batteries.

This 9-page document from MNRE’s Standards and Quality Control Division (File No. 313-12/10/2025-S AND QC) sets out those rules for the 2025 order. It covers lead-acid, lithium-ion (portable and industrial) and nickel-based batteries. It follows the 2019 guidelines written for IS 16270:2014, which had no lithium-ion rules. MNRE circulated it as a draft for comments in September 2025.

What a product family is

A product family is defined by the maximum configuration of components and sub-assemblies, plus a description of how each model is built from it. All the models in a family should share the design, construction, parts or assemblies that make them conform.

To put batteries in one series, the manufacturer gives the laboratory an undertaking that all the models were made with no change in grid alloy composition, grid purity, grid thickness, ingredients used to prepare the electrodes, the method of preparation and thickness of the electrodes, or the quality systems followed. The wording is written for lead-acid batteries, but clause 5 applies it to all cells and batteries.

Lithium-ion series

Table 4 groups lithium-ion cylindrical, prismatic and pouch cells and batteries by rated capacity. The highest rating in each series is its representative model.

SeriesRated capacity
AUp to 20 Ah
BAbove 20 Ah to 100 Ah
CAbove 100 Ah to 500 Ah
DAbove 500 Ah to 1000 Ah
EAbove 1000 Ah

Clause 3.7 covers lithium-ion and other chemistries, for portable use under IS 16047 (Part 3) and industrial use under IS 16822. For each sample the manufacturer gives the laboratory:

  1. The type and material of the container.
  2. The lithium-ion chemistry or technology.
  3. The material of the separator.
  4. The overall dimensions and weight of each complete cell or battery.
  5. The nominal voltage and rated capacity.

The cells or batteries submitted as a batch must have the same nominal voltage, electrolyte composition and overall dimensions. The manufacturer supplies connectors for each cell and its recommended charging procedure. Cells are marked under clause 5.3 of IS 16047 (Part 3) for portable use or clause 5.1 of IS 16822 for industrial use. Battery pack enclosures must be flame-retardant and impact-resistant.

The tables group by capacity alone and do not say whether packs of different nominal voltage, such as 12.8 V, 25.6 V and 51.2 V lithium iron phosphate packs, can share a series. Settle the grouping with the laboratory before samples go in.

Lead-acid series

Table 2 sets bands for each type of lead-acid cell or battery. The representative model is the top of the band (400 Ah for series A of 2 V flooded cells, for example) or the highest rating in the series.

TypeABCD
2 V flooded cellsUp to 400 AhAbove 400 to 700 AhAbove 700 to 1000 AhAbove 1000 Ah
2 V VRLA cellsUp to 200 AhAbove 200 to 500 AhAbove 500 to 1000 AhAbove 1000 Ah
12 V flooded batteriesUp to 20 AhAbove 20 to 100 AhAbove 100 Ah
12 V VRLA batteriesUp to 50 AhAbove 50 to 100 AhAbove 100 Ah

In the top band of each type, the highest rating in the series is tested. Samples in a batch must share nominal voltage, rated capacity, electrolyte composition, specific gravity and overall dimensions, as set out in IS 13369 or IS 1651 for vented batteries and IS 15549 for valve regulated ones.

Nickel series

Table 3 groups vented nickel-cadmium and nickel-metal hydride cells and batteries into four bands (up to 45 Ah, above 90 to 500 Ah, 500 to 1000 Ah, above 1000 Ah), and nickel-cadmium prismatic single cells with partial gas recombination into three (above 90 to 500 Ah, 500 to 1000 Ah, above 1000 Ah). The highest rating in each series is tested. As printed, the table has no band for 45 to 90 Ah, as in the 2019 version.

How the series is tested

  • The representative model, the highest rated capacity in the series, gets every type test in Table 6 of IS 16270:2023, endurance tests included.
  • Every rating in the series gets the short-term tests, such as the capacity test. A rating that fails one is resubmitted.
  • Test reports go to every model in the series once the representative model passes.
  • Samples are picked at random by the laboratory from a production batch, in the numbers set by clause 8.4.1 and Table 6 of IS 16270:2023. Pass criteria follow clauses 8 and 9.
  • Charging follows the manufacturer’s recommended procedure, and the temperature and humidity limits in clause 4.3.9 of IS 16270, or Table 2 of the standard if the manufacturer gives none.

Safety information

Section 6 lists the safety and other information the manufacturer or supplier must provide for batteries used in photovoltaic systems. It includes the voltage range and load pattern, charging conditions, size, weight, terminal type, operating life and storage period. It also covers how far the battery bank can be expanded, the electric shock hazard, the upper DC voltage limit for domestic and non-domestic installations, and the procedure for disposal and recycling. Parallel-connected battery systems each need an isolator.

The 2019 guidelines

MNRE’s guidelines of 27 June 2019 (File No. 223/28/2018-R&D Coord.(QC)) did the same job under the 2017 solar order and IS 16270:2014. They covered lead-acid and nickel batteries only, with the same capacity bands as the 2025 version, and listed the short-term tests for stationary lead-acid batteries as capacity, retention of charge, sulphation and water loss. Download the 2019 guidelines (7 pages, official copy).

Status

The 2025 version is a draft, and we have not found a final one. It is the only MNRE document that groups lithium-ion solar batteries, so confirm with the laboratory how it is applying it. Amendment No 1 to IS 16270:2023 also limits the standard to off-grid solar use and adds a 0.2 It discharge for lithium batteries: see the IS 16270:2023 guidelines. Inverters have their own MNRE series guidelines.

Products this document applies to

Each product page shows the Indian Standard, the notifying order and how to register.

About IS 16270 and its BIS labs

Frequently asked questions

How are lithium-ion solar batteries grouped into a series?

By rated capacity, in five bands: up to 20 Ah, above 20 to 100 Ah, above 100 to 500 Ah, above 500 to 1000 Ah, and above 1000 Ah. The band covers cylindrical, prismatic and pouch cells and batteries, and the highest rating in each series is its representative model.

Which tests does each model in a series need?

The highest-rated model gets every type test in Table 6 of IS 16270:2023, endurance tests included. Short-term tests such as the capacity test are done on every rating in the series, and a rating that fails one is resubmitted. When the representative model passes, the lab issues test reports for all the models in the series.

Can battery packs of different voltages share one series?

The guidelines do not say. The series tables group batteries by capacity only, but the cells or batteries submitted together as a batch must have the same nominal voltage, electrolyte composition and overall dimensions. Agree the grouping of 12.8 V, 25.6 V and 51.2 V packs with the laboratory before sending samples.

Are the 2025 series guidelines final?

MNRE circulated them as a draft for comments in September 2025. MNRE's policy update of January 2026 lists final series guidelines for SPV modules, issued on 19 December 2025, but none for batteries, and we have not found a final battery version since.

More in Solar PV

Also on our CRS guidelines page: Series guidelines · CRS FAQs · IS/IEC 62368-1:2023 migration · Product standards

All CRS guidelines and FAQs

Related guides from our team

This page is our summary of an official document, written for general guidance. The PDF is the authoritative text. BIS and MeitY revise these documents from time to time, so check the official source or speak to our team before acting. Published 29 September 2025.

Planning a CRS registration?

We group your models, choose the lead models and file on the CRS portal, so testing runs once.

Call WhatsApp Get a quote